The overall goal of this study is to evaluate the use of dopamine transporter (DAT) imaging as a diagnostic tool in subjects with early parkinsonian symptoms, in whom Parkinson's disease (PD) or parkinsonian syndrome (PS) is suspected, but the diagnosis remains unclear from a clinical standpoint.
* Subjects will be referred to the Institute for Neurodegenerative Disorders (IND) by practicing general neurologists with genuine uncertainty regarding the subject's diagnosis. * Subjects with suspected PD or PS will be evaluated clinically and with DAT imaging, using b-CIT and SPECT. The DAT imaging procedure will take place over two days: * On the first day participants are injected with \[123I\]ß CIT, an investigational radioactive material that localizes in the brain. Study participants will also have a thorough neurologic examination and standard neuropsychological testing, including testing of memory, concentration, abstraction and visual spatial functions. * Twenty-four hours later study participants return to the Institute for Neurodegenerative Disorders where an investigational scanning procedure will be used to obtain SPECT (single photon emission computed tomography) images of the brain. * Subjects will be asked to return within 3 months following the imaging study to have a repeat neurological examination by the two study neurologists at IND. * Subjects will be asked to return at about 6 months and possibly again at one year following the imaging study for a final clinical evaluation by one of the study neurologists at IND.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DIAGNOSTIC
Masking
SINGLE
Enrollment
169
Single Photon Emission Computed Tomography SPECT imaging uses the single photon emissions from radioactive compounds that are (most commonly) injected into a patient and are metabolized by specific organs or body systems. SPECT imaging is performed by using a gamma camera to acquire multiple 2-D images (also called projections), from multiple angles. A computer is then used to apply a tomographic reconstruction algorithm to the multiple projections, yielding a 3-D dataset. This dataset may then be manipulated to show thin slices along any chosen axis of the body, similar to those obtained from other tomographic techniques, such as MRI, CT, and PET. The resulting SPECT images reflect body/organ function as opposed to specific anatomy of other imaging modalities such as CT or MRI.
Institute for Neurodegenerative Disorders
New Haven, Connecticut, United States
Comparison of the imaging diagnosis, based on visual analysis and quantitative analysis, to the clinical diagnosis of the investigator blinded to the imaging results
Time frame: 5 years
Comparison of the DAT imaging diagnosis, initial diagnosis by the movement disorder experts and referral neurologist diagnosis to the 'gold standard' diagnosis
Time frame: 5 years
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.