The aim of the study is to observe the ventilatory and cardiac function (included the pulmonary arterial pressure) during an intermittent work exercise test with high density work load.
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
PREVENTION
Masking
NONE
Enrollment
10
Hôpitaux Universitaires de Strasbourg - Service des Explorations Fonctionnelles
Strasbourg, France
The pulmonary arterial pressure does not increase dramatically during the 30 minutes exercise test, but decreases significantly after the first 5 minutes of exercise.
The cardiac output is stable after the first 5 minutes of exercise, despite the high intensity work loads every 5 minutes.