The purpose of this randomized clinical trial was to examine the efficacy of a splinting (fabricated versus off-the-shelf splint)and exercise (nerve and tendon gliding versus no exercise) interventions to alter the clinical course of Carpal Tunnel Syndrome (CTS). We hypothesized that the fabricated splint with nerve and tendon gliding exercises condition would yield the best functional outcomes at 4 and 8 weeks posttesting.
The purpose of this randomized clinical trial is to examine the efficacy of a splinting and exercise intervention to alter the clinical course of Carpal Tunnel Syndrome (CTS). Specifically, the aims of the study are to test the efficacy of: (1) a splint, positioning the wrist and metacarpal phalange (MCP) joints at 0 degrees in conjunction with tendon and nerve gliding exercises, (2) a splint positioning the wrist and MCP joints at 0 degrees with no exercise (3) a prefabricated wrist cock up splint positioning the wrist at 20 degrees of extension with tendon and nerve gliding exercises, and (4) usual care, a prefabricated wrist cock-up splint positioning the wrist at 20 degrees of extension with no exercise for decreasing symptoms and increasing function in people with clinically diagnosed CTS. The specific hypotheses of the study are: (1) Subjects randomized to Experimental Condition 1 will perform better than Subjects randomized to Experimental Condition 2; who will perform better than those randomized to Experimental Condition 3, who in turn will perform better than those Subjects randomized to Usual Care. In that order, Subjects will demonstrate a: 1. Significant decrease in CTS symptoms as measured by the Carpal Tunnel Syndrome Symptom Severity Scale at the 4 week Posttest compared to baseline and further decrease at the 8 week Post-Posttest. 2. Significant decrease in upper extremity disability as measured by the Disability of Arm, Shoulder, and Hand (DASH) questionnaire at the 4 week Posttest compared to baseline and further decrease at the 8 week Post-Posttest. 3. Significant increase in functional ability as measured by functional sensibility (Moberg Pick-Up Test), grip strength (dynamometer) and pinch strength (pinch meter) at the 4 week Posttest compared to baseline.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
56
Experimental: Custom-made splint and tendon-nerve gliding exercises Custom-made splint and no tendon-nerve gliding exercises Control: Control: Off-the-shelf splint and tendon-nerve gliding exercises Off-the-shelf splint and no tendon-nerve gliding exercises
Carpal Tunnel Syndrome Symptom Severity & Functional Status Scale
Self-report tool
Time frame: Pre-Post
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.