The aim of this study is to examine removal of protein bound uremic substances by mFPSA in chronic hemodialysis patients. mFPSA is an extracorporal blood purification system developed for detoxification in acute liver failure by removal of protein bound as well as water soluble substances.
Measurements of uremic protein bound substances before and after mFPSA and a preceding routine hemodialysis session.
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
10
Rigshospitalet
Copenhagen, Copenhagen, Denmark
RECRUITINGBlood pressure
Safety serological parameters
Concentrations of protein bound uremic toxins
Bleeding episodes