To compare manual administration of propofol and remifentanil and dual closed-loop using bispectral index as the control variable during anesthesia
The Bispectral Index (BIS) is an electroencephalogram-derived measure of anesthetic depth. A closed-loop anesthesia system can be built using BIS as the control variable, a proportional-integral-differential control algorithm, and a propofol target-controlled infusion system as the control actuator. Recent studies have shown that such system is able to provide clinically adequate anesthesia. We hypothesized that BIS can also indicate the adequacy of analgesia and therefore built a combined closed-loop anesthesia system using BIS as the control variable, two proportional-integral-differential control algorithms, a propofol and a remifentanil target-controlled infusion systems as the control actuators. In preparation for a large multi-center control trial, we propose a prospective randomized study to evaluate the effectiveness of such a closed-loop anesthesia system. Two groups of patients are compared: one in which propofol and remifentanil are administered by the anesthesiologist using target-controlled infusion systems, and one in which propofol and remifentanil are administered automatically by the combined closed-loop anesthesia system. In both groups, the goal is to maintain BIS between 40 and 60, the recommended range during anesthesia by the manufacturer. We expect the combined closed-loop anesthesia system group to do similar or better.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
240
Dept of Anesthesia, CH d'Argenteuil
Argenteuil, France
Dept of Anesthesiology, CHU de Besançon
Besançon, France
Dept of Anesthesia, Clinique Saint Augustin
Bordeaux, France
Dept of Anesthesia and Intensive Care, Hôpital Beaujon
Clichy, France
Global score (calculated parameter which depicts the performance of the system, i.e. its capacity to maintain BIS in the desired range)
consumption of propofol and remifentanil during the induction and the maintenance of the anaesthesia
number of modifications of target of propofol and remifentanil
number of episodes of hemodynamic anomalies having required a treatment
intraoperative volume loading and transfusion
extubation time, explicit memorisation
dysfunctions of each system
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Dept of Anesthesiology, Hôpital Cochin
Paris, France
Dept of Anesthesia, Hôpital Foch
Suresnes, France