RATIONALE: A computer-aided detection program may help doctors find breast cancer sooner, when it may be easier to treat, in women undergoing screening mammography. PURPOSE: This randomized clinical trial is studying how well computer-aided breast cancer detection works in women undergoing screening mammography.
OBJECTIVES: * Compare, prospectively, the breast cancer detection rate and recall rate of single reading using computer-aided detection vs standard double reading in women undergoing screening mammography. OUTLINE: This is a prospective, randomized, multicenter study. Participants are randomized to 1 of 3 screening arms. * Arm I (double reading): Screening mammograms are independently reviewed by two readers (i.e., radiologist or radiographer), each of whom reports on any abnormalities and decides whether a participant is recalled for further assessment or returned home to routine screening. In the event there is disagreement between the readers' findings, a third reader acts as an arbitrator by rendering an interpretation of the mammogram and making the final decision to recall the participant or return to routine screening. * Arm II (single reading with computer-aided detection \[CAD\]): Screening mammograms are reviewed initially by a single reader who reports on any abnormalities. The reader then re-examines the mammogram with the aid of CAD, a system that uses computer prompts to recall suspicious features or abnormalities that may have been overlooked or previously dismissed as being normal. Based on these evaluations, a recommendation is made by the reader to either recall the participant for further assessment or return home to routine screening. If there is a discrepancy between the reader's interpretation and the CAD findings, another reader may be consulted to review the mammogram. * Arm III (double reading followed by single reading with CAD): Screening mammograms are reviewed by double reading as in arm I followed by single reading with CAD as in arm II. Peer Reviewed and Funded or Endorsed by Cancer Research UK PROJECTED ACCRUAL: A total of 30,000 participants will be accrued for this study.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
SCREENING
Enrollment
30,000
Walsgrave Hospital
Coventry, England, United Kingdom
Withington Hospital
Manchester, England, United Kingdom
Nottingham City Hospital NHS Trust
Nottingham, England, United Kingdom
Aberdeen Royal Infirmary
Aberdeen, Scotland, United Kingdom
Breast cancer detection rate
Recall rate
Film reader performance using computer-aided detection
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.