Patients with chronic hypercapnic respiratory failure can be successfully treated with home nocturnal non-invasive ventilation. Bi-level pressure support ventilators are at present the most frequently used ventilators for long term home ventilation. A recently commercialized bi-level ventilator offers the feature of automatically adjusting pressure support on the basis of a pre-determined ideal effective ventilation. Because this option may induce important swings in pressure support, and thus patient discomfort, and maybe increase leaks, we chose to analyse the impact of average volume assured pressure support (AVAPS) on patient comfort, subjective and objective quality of sleep and efficacy of ventilatory support.
This study aims to compare, in a randomized order, two consecutive nights with a bi-level positive pressure ventilator (Synchrony, Respironics, USA), with and without average volume assured pressure support (AVAPS), in patients with chronic respiratory failure, treated on a long term basis by home nocturnal non-invasive ventilation. Specific endpoints are : * quality of sleep assessed by polysomnography scored by an independent investigator (sleep efficiency, distribution of sleep stages, arousals and sleep stage changes) and subjective scores (St Mary's questionnaire), * perception of comfort of ventilation (clinical score), * efficacy of ventilation (pulsoximetry, transcutaneous capnography (Tina TCM4 Radiometer, Copenhagen), effective ventilation and tidal volumes, leaks as measured by ventilator, Stardust software, Respironics). Patients: Fourteen patients with obesity-hypoventilation and/or COPD, treated and stable for at least 3 months, will be included and undergo complete sleep studies in Geneva University Hospital's Sleep Laboratory. Patients included must be compliant to treatment (at least 4 hours of use of ventilator/night). Methods: Patients are blinded as to whether or not AVAPS is implemented. Target tidal volume is set at 7-8 ml/kg. EPAP (Expiratory positive airway pressure) level is unchanged. Minimal IPAP (Inspiratory positive airway pressure) level is set at usual IPAP - 3 cm H2O. Maximal IPAP is set between 25 and 30 cm H2O. Back up frequency is unchanged. All patients must provide written informed consent. Protocol has been accepted by the ethics committee on clinical research of Geneva University Hospital. Results of scores, and relevant parameters of polysomnography, oxymetry, and capnography, will be compared.
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
SUPPORTIVE_CARE
Masking
SINGLE
Enrollment
14
Sleep Laboratory; Department of Psychiatry, Geneva University Hospital
Chêne-Bourg, Canton of Geneva, Switzerland
Quality of sleep
Time frame: One night
Efficacy of ventilation
Time frame: One night
Patient comfort
Time frame: One night
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.