Confocal laser endomicroscopy (CLE) is a new diagnostic technique that allows microscopic examination of the digestive mucosa during ongoing endoscopy. Different types of tissue and diseases can be diagnosed immediately, and analysis of the in vivo microarchitecture is helpful to better target standard biopsies and reduce the number of biopsies required. CLE necessitates an intravenous injection of a fluorescent marker, e.g. fluorescein, to obtain 'optical biopsies' with a high level of magnification (up to 1000 fold). To date, more than 1000 endomicroscopy procedures have been performed in the world and different publications have shown the safety, feasibility and excellent diagnostic yield of CLE. No complication related to IV injection of fluorescein has been reported. However, all these data come from a very limited number of expert centres and need to be confirmed and validated at the multicenter level. The aims of this multicenter trial are: 1) to standardize CLE in all centres equipped in France, 2) to ensure the safety of intravenous fluorescein injection, 3) to test the diagnostic value of CLE in various conditions representative of the large spectrum of different cancerous and non-cancerous digestive diseases.
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
61
microscope with a confocal window in its distal part. During ongoing endoscopy, 5 mL of 10% fluorescein (Novartis) will be injected intravenously to perform CLE imaging. In brief, CLE images are obtained few seconds after fluorescein injection by gentle positioning of the confocal window in contact with the digestive mucosa. To stabilize images, some suction can be applied using the operating channel of the endoscope. CLE images ('optical biopsies') will be stored and 1-2 standard biopsies will be performed in the examined area in order to further compare optical and standard biopsies. The overall duration of the procedure will be limited to 1 hour. During and after the procedure, patients will be monitored and surveyed continuously by anaesthesiologist. General tolerance and potential late adverse events will be assessed by the careful inquiry performed 1 month after the procedure by consultant gastroenterologist.
After obtaining a written informed consent from all the patients, standard upper GI endoscopy or colonoscopy will be performed under general anaesthesia using a videoendoscope EC-3870 (Pentax), which includes a miniaturized microscope with a confocal window in its distal part. During ongoing endoscopy, 5 mL of 10% fluorescein (Novartis) will be injected intravenously to perform CLE imaging. In brief, CLE images are obtained few seconds after fluorescein injection by gentle positioning of the confocal window in contact with the digestive mucosa. To stabilize images, some suction can be applied using the operating channel of the endoscope. CLE images ('optical biopsies') will be stored and 1-2 standard biopsies will be performed in the examined area in order to further compare optical and standard biopsies. The overall duration of the procedure will be limited to 1 hour. During and after the procedure, patients will be monitored and surveyed continuously by anaesthesiologist.
Service d'Hépato-Gastroentérologie, Centre Hospitalier Lyon Sud
Lyon, France
Service d'Hépato-Gastroentérologie, Institut Paoli Calmettes
Marseille, France
Service d'Hépato-Gastroentérologie, CHU Nantes
Nantes, France
Service d' hépato-gastro-entérologie, CHU de ROUEN
Rouen, France
CHU de Rangueil
Toulouse, France
To establish a safe and standardized practice of CLE in France, which should give a possibility, by providing high quality optical biopsies, to perform in vivo diagnosis of different digestive diseases
To assess the tolerance of CLE in terms of frequency and gravity of potential adverse events related to the injection of fluorescein
To assess the diagnostic yield of CLE in various clinical conditions (cancerous and non-cancerous diseases) by comparing optical biopsies with standard histology
To assess the interobserver agreement for this technique, using a database of optical biopsies created at the end of the study
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.