Fractures just below the hip often are treated with a so called Gliding Screw and Plate (DHS). Recently a new additional plate called a Trochanter Support Plate (TSP) which attaches to the DHS has become available which is claimed to give extra support to the fracture. In a prospective randomised study we wish to test the hypothesis that the TSP does not give any additional stability to the fracture treated with the DHS.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
100
All patients operated with DHS. Of these two groups. One operated with TSP and one without.
Ortopaedic Department, St.Olavs Hospital
Trondheim, Norway
Fracture movement postoperatively
Time frame: One year
Reoperation
Time frame: One year
Pain postoperatively
Time frame: one year
Hip function postoperatively
Time frame: one year
Fracture healing
Time frame: one year
complications postoperatively
Time frame: one year