The purpose of this study will explore the advantages of electrodes used for monitoring of the recurrent laryngeal nerve (RLN) in thyroid surgery
OBJECTIVES/HYPOTHESIS: The purpose of this study will explore the advantages and applications of electrodes used for monitoring of the recurrent laryngeal nerve (RLN) in thyroid surgery. We want to know that if the monitoring system will decrease the rate of recurrent laryngeal nerve palsy. STUDY DESIGN: One hundred patients who undergoing thyroid surgery will be collected in this study. Patients will be intubated for general anesthesia with a Medtronic Xomed Nerve Integrity Monitor (NIM) EMG endotracheal tube (Jacksonville, Fla) that had 2 electrodes imbedded in the wall of the endotracheal tube. These wires were placed up against each vocal cord. Two grounding wires(needle No. 26) were placed up in the subcutaneous tissues of both shoulders. The electrode wires, grounding wires, and nerve stimulator were connected to a monitoring device (Medtronic NIM-Response) that recoded a visual evoked potential and audible beep to each muscle contraction of a vocal cord. A Medtronic Xomed Prass monopolar nerve stimulator wand was used to test the RLN intraoperatively and was set at 0.5mA. Direct physical touching of the RLN with nerve stimulator using pulsed current would produce an audible "beep-beep-beep". CONCLUSION: This study will be conducted in cooperation with Department of anesthesiology. The following subjects will be collected and elucidated: 1. If the muscle relaxant used during surgery will affect the operation of RLN monitoring system. 2. Can RLN monitoring system accurately identify the RLN 3. Can RLN monitoring system accurately predict the function of RLN 4. Can RLN monitoring system decrease the RLN palsy rate after thyroidectomy 5. Application of RLN monitoring to determine the safety and the benefit of vagal stimulation at the beginning and the end of thyroid operation 6. Application of RLN monitoring to determine whether extensive dissection of RLN increases the risk of nerve injury. At least four papers will be written after this study with the topics as followings: 1. Influence of muscle relaxation on neuromonitoring of the recurrent laryngeal nerve during thyroid surgery 2. Intraoperative neuromonitoring of the recurrent laryngeal nerve during thyroid surgery: Plaudits and pitfalls 3. Vagal stimulation during intraoperative neuromonitoring of the recurrent laryngeal nerve in thyroid operation. 4\. Does extensive dissection of recurrent laryngeal nerve during thyroid operation increase the risk of nerve injury? Our experience with the application of intraoperative neuromonitoring
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
PREVENTION
Masking
NONE
Enrollment
1,000
patients receive surgery will be intubated with Medtronic Xomed NIM EMG endotracheal tube and the device will be connected to the monitoring system 1. The channel leads from the NIM EMG reinforced endotracheal tube were connected to a NIM-response monitor 2. A Prass monopolar probe was used in direct contact with the vagus nerve and RLN for laryngeal nerve stimulation. 3. The stimuli were generated from the NIM-Response monitor for vagal and RLN stimulation. 4. The NIM-response monitor was set to run with a 50 millisecond time window and an amplitude scale at 0.2 mV/division. Event capture was activated with a threshold at 100 μV. Peak to peak amplitudes of evoked EMG activities were directly read on the monitor screen.
Department of Otolaryngology- Head and Neck Surgery, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Taiwan
Kaohsiung City, Kaohsiung City, Taiwan
RECRUITINGIf the muscle relaxant used during surgery will affect the operation of RLN monitoring system.
Time frame: during operation
Can RLN monitoring system accurately predict the function of RLN Can RLN monitoring system decrease the RLN palsy rate after thyroidectomy
Time frame: early postoperation period
Can standardization of IONM procedures further lower the RLN palsy rate
Time frame: early postoperation period
Dose IONM help to decrease the RLN palsy rate during difficult thyroid operations
Time frame: early postoperation period
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.