Despite widely used of nasal CPAP in preterm infants, uncertainties regarding aspects of its application remain. Clinical indications vary greatly between institutions, especially when combined with varieties of systems, devices, and techniques available. One of the controversial aspects that needs to be clarified is the level of pressure which should be used. The objective of the study is to compare the effectiveness of two ranges of nCPAP pressure that are within the spectrum of current practice for post-extubation support in very preterm infants.
The use of nCPAP has been established as an effective respiratory support to prevent extubation failure and as treatment of other pulmonary diseases. An upsurge in its popularity has resulted in some controversial aspects, including the level of pressure to be used. The level that has been used in very preterm infants after extubation, which mostly came from anecdotal data, varies from 3 to 10 cmH2O. Physiologic studies show higher nCPAP pressures improve lung mechanical properties. Though potential side effects have been of concern in practical application, there is no formal evidence supporting the concept that increased CPAP pressure results in a higher risk of complications. In relatively stable preterm infants, the range of optimal CPAP level needs to be established in order to adequately support the upper airway and lungs, without increasing complications secondary to the pressure applied. Given the uncertainty of the nCPAP pressure that should be used in very preterm infants, we conduct a randomized controlled trial to compare the effectiveness of two ranges of nCPAP pressure for post-extubation support in very preterm infants. The purpose of this trial is to compare the rate of successful extubation of using the nasal CPAP level of 7 to 9 cmH2O compared to level of 4 to 6 cmH2O.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
23
Apply nasal CPAP pressure of 7-9 H2O for the first 72 hours of extubation
Apply nasal CPAP pressure of 4 to 6 cmH2O for the first 72 hours of extubation
The rate of successful extubation within 72 hours of extubation
Time frame: within 72 hours after extubation
The rate of successful extubation within 7 days of extubation
Time frame: within 14 days after extubation
Number of days on nCPAP
Time frame: within 14 days after extubation
Occurrence of air leak syndrome
Time frame: within 14 days after extubation
Occurrence of IVH grade 3 or 4
Time frame: within 14 days after extubation
Occurrence of traumatized nasal septum
Time frame: within 14 days after extubation