the purpose of this study was to compare standard trabeculectomy to the Ex-PRESS mini glaucoma shunt implantation under a scleral flap in eyes with open-angle glaucoma.In this report, we describe the results of a prospective, randomized trial in which subjects with bilateral primary open-angle glaucoma underwent the two procedures in fellow eyes.Design: Prospective, randomized clinical trial. Participants: 15 subjects with bilateral primary open-angle glaucoma Methods: Subjects underwent the two procedures in fellow eyes. Safety and efficacy were evaluated for up to two years. Main Outcome Measures: Mean IOP and surgical success rates. Results: Mean IOP was similar in Ex-PRESS and trabeculectomy eyes at all time points except month 9, when Ex-PRESS eyes had lower mean IOP (13.2 mmHg vs 16.5 mmHg, respectively; p=0.025). Percent IOP reduction was also similar at all time points except postoperative day 1, when trabeculectomy eyes were lower (75.5% vs 65.8%, respectively; p=0.003), likely due to a higher rate of early hypotony in trabeculectomy eyes versus Ex-PRESS eyes (47% vs 7%, respectively). Complete (without medications) and qualified (with or without medications) successes were more common at all IOP cut-off values in Ex-PRESS eyes than trabeculectomy eyes at last visit (p=0.015, p=0.015 respectively). Postoperative complications were uncommon in both groups, but trabeculectomy eyes required more postoperative interventions than Ex-PRESS eyes.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
30
I. Mobility check of the device. II. Administration of a local or topical anesthetic. III. Preparation and coverage of the eye by conventional sterile procedures. IV. Injection of viscoelastic material into the AC through a paracenthesis. V. Creation of a scleral tunnel up to clear cornea. VI. Creation of a (5 mm) conjunctival tunnel fornix based. VII. Lifting of the conjunctiva and tenon. VIII. Formation of a 2mm scleral incision at 0.3mm depth, 1.5mm from the limbus. IX. Application of 0.5µg/ml MMC under the tunnel for one minute. X. Penetration into the AC using a 0.65mm stiletto, inside the tunnel of the sclera-corneal junction. XI. Implantation of the Ex-PRESSTM through that pre-incision at the sclerocorneal junction. XII. Introducer withdrawal. XIII. Tucking the plate under the scleral tunnel, and verification of the position inside the tunnel. XIV. Reposition the conjunctiva with 1 - 2 sutures at the limbus. XV. Closing the conjunctiva with a suture.
standard trabeculectomy
Department of Ophthalmology, University of the Witwatersrand,
Johannesburg, South Africa
Mean IOP and surgical success rates. na
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.