The objective of this study is to evaluate the completeness of struts coverage and vessel wall response (strut malapposition, neointima disomogeneities in texture) to the ENDEAVOR drug-eluting stent vs the DRIVER stent (bare metal stent of identical metallic platform) implanted for the treatment of the culprit lesion in ST-elevation acute myocardial infarction (STEMI). To investigate the completeness of the coverage as well as the number of uncovered stent struts per section (embedded, uncovered, malapposed) and the neointima texture, high resolution (\~ 10-15 µm axial) intracoronary optical coherence tomography (OCT)will be used.
Major concerns have been raised with regard to the safety of drug-eluting stents (DES) in patients with ST-elevation acute myocardial infarction (STEMI). Data from registry studies have suggested that implantation of DES during primary PCI could be associated with an increased risk for stent thrombosis, probably due to delayed arterial healing. Unlike first generation DES, zotarolimus-eluting stents seems to be associated with complete and uniform neointimal coverage. The objective of this prospective study is to measure the completeness of strut coverage and vessel wall response to the ENDEAVOR zotarolimus-eluting stent vs the DRIVER stent (bare metal stent of identical metallic platform) implanted in STEMI patients. Optical Coherence Tomography (OCT) that detects smaller degrees of stent strut coverage more accurately than IVUS will be used at 6 months follow-up. Intravascular ultrasound (IVUS) will be performed as per normal practice at any index procedures and at 6 months follow-up.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
44
ENDEAVOR® drug-eluting stent implanted in acute myocardial infarction
DRIVER bare metal stent implanted in acute myocardial infarction
Comparison of Drug Eluting versus Bare Metal Stent
Comaprison between Drug Eluting and Bare Metal Coronary Stents
Ospedali Riuniti di Bergamo
Bergamo, Italy
Non inferiority OCT Number of uncovered Stent struts for Endeavor drug eluting stent vs Driver BMSbare metal stent
Non inferiority
Time frame: 6 months
number of well apposed stent struts without neointima
number of well apposed stent struts without neointima
Time frame: 6 months
number of malapposed stent struts without neointima
number of malapposed stent struts without neointima
Time frame: 6 months
number of sections with > 30% uncovered struts/total struts
number of sections with \> 30% uncovered struts/total struts
Time frame: 6 months
Number of sections with incomplete strut apposition
Number of sections with incomplete strut apposition
Time frame: 6 months
Adjudicated MACE(Death, re-MI, TLR) rate at 30 days and 6 months (non inferiority)
Adjudicated MACE(Death, re-MI, TLR) rate at 30 days and 6 months (non inferiority)
Time frame: 6 months
In segment OCT neontimal volume
In segment OCT neontimal volume
Time frame: 6 months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.