The objective of this study is to evaluate the completeness of struts coverage and vessel wall response to the new generation JACTAX drug-eluting stent vs Taxus stent in de novo coronary artery lesions at 6 months post index procedure. To investigate the completeness of the coverage as well as the number of uncovered stent struts per section, high resolution (\~ 10-15 µm axial) intracoronary Optical Coherence Tomography (OCT) will be used.
The risk of late stent thrombosis represents a major concern for patients treated with first generation drug-eluting stents (DES). Delayed healing and poor endothelialization are common findings in vessels treated with DES and are probably related to the amount of drug and polymer applied to a DES. There is evidence to suggest that polymer applications may influence the processes of inflammation and vessel healing. The JACTAX family of DES have been designed to provide a maximum amount of drug delivered directly to coronary vessel tissue while excluding polymer and drug from contact within the vessel lumen. The JACTAX stents are comprised of a currently marketed bare metal stent (Libertè™) coated exclusively on the ablumenal stent surface with a carrier containing a bioerodable polymer, Polylactide and paclitaxel. The objective of this prospective study is to measure the completeness of strut coverage and vessel wall response (strut malapposition, neointima disomogeneities in texture) to the JACTAX stents vs Taxus Libertè in de novo coronary artery lesions at 6 months post index procedure. Optical Coherence Tomography (OCT) that detects smaller degrees of stent strut coverage more accurately than IVUS will be used at 6 months follow-up. Intravascular ultrasound (IVUS) will be performed as per normal practice at any index procedures and at 6 months follow-up.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
60
Jactax stent placed in coronary artery
JACTAX LD stent placed in coronary artery
Taxus Libertè stent placed in coronary artery
Ospedali Riuniti di Bergamo
Bergamo, Italy
Proportion of stent struts uncovered and/or malapposed at OCT
Time frame: 6 months
Major Adverse Cardiac Events (MACE)
Time frame: 12 and 24 months
Stent Thrombosis
Time frame: 12 and 24 months
Target Lesion Revascularization
Time frame: 12 and 24 months
Procedural success
Time frame: through discharge
QCA parameters: mean lumen diameter, acute gain, late loss and binary restenosis (≥ 50% diameter stenosis) rate
Time frame: 6 months
IVUS parameters: neointimal area volume, stent and area volumes, stent apposition, and percent net volume obstruction
Time frame: 6 months