OBJECTIVES: The primary objective of this study is to assess the safety and efficacy of the Supralimus - Core™ Sirolimus Eluting Stent in de novo native vessel obstructive coronary artery disease. STUDY DESIGN: This is a single centre, prospective study. Approximately 105 patients were enrolled in the study. Patients were followed for twelve months post-procedure. All patients were to have a repeat angiography at 8 months. STUDY POPULATION: The study population consisted of approximately 105 patients with de novo native vessel obstructive coronary artery disease with no specific criteria. Patients from the daily practice were included. Patients had to meet all eligibility criteria for inclusion into the study. ENDPOINTS: The primary safety endpoint of the study is defined as Major Adverse Cardiac Events (MACE) at 30 days. The primary efficacy endpoint is the in-stent binary restenosis rate at 8-month follow-up determined by off-line Quantitative Coronary Angiography. The following secondary efficacy endpoints were assessed * Angiographic success * Procedure success * Quantitative Coronary Angiography derived vessel parameters in-stent and 5 mm proximal and 5 mm distal from the edge of the stent: acute gain, MLD, % DS, late loss, mean diameter. In-stent pre-, post and at 8-month follow-up. * Clinically justified Target Lesion Revascularization (TLR) at 12 months The following secondary safety endpoints were assessed: * MACE until 12 months * Device related SAEs until 12 months * Angiographic stent thrombosis: Subacute (after procedure until 30 days) and Late (after 30 days until 12 months)
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
105
Sirolimus Eluting Cobalt Chromium based coronary stent system
Supralimus™ Core™ Sirolimus eluting stent intended to treat coronary artery disease.
Max Heart and Vascular Institute
New Delhi, New Delhi, India
Primary safety endpoint: Major Adverse Cardiac Events (MACE)
Time frame: 30 days
Primary efficacy endpoint: In-stent binary restenosis rate determined by off-line Quantitative Coronary Angiography.
Time frame: 8 Month
Secondary safety endpoints: - MACE until 12 months, Device related SAEs until 12 months, Angiographic stent thrombosis: Subacute (after procedure until 30 days) and Late (after 30 days until 12 months)
Time frame: 12 months
Secondary efficacy endpoints: Angiographic, Procedure success; acute gain, MLD, % DS, LL, mean diameter; In-stent pre-,post,8-month follow-up; Clinically justified TLR at 12 months
Time frame: 12 months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.