The C-Pulse Feasibility Study is evaluating the safety and performance of a new product for the treatment of heart failure. The product is designed to help reduce the symptoms of heart failure and help patients function better with daily activities. The study evaluates multiple measures of heart function and whether the patient's quality of life has been improved since the device implant. The patient will have several visits after the device implant to assess how well they are doing and to monitor any safety concerns.
Sunshine Heart Inc. is sponsoring a prospective, multi-center trial to assess the safety and provide indications for performance of the Sunshine Heart C-PulseTM System ("C-Pulse™"). The current need is for a counterpulsation device or method that is effective enough to make its application appealing as a long-term implant to a large number of patients and physicians. It must be simple and safe, with a straight-forward implant procedure, and with long-term measurable patient benefits. Further, it would be advantageous for the counterpulsation device to be smaller, easier to insert, ambulatory, disconnectable, and not in the bloodstream. Such a device may be more readily adopted by a wider group of cardiologists and surgeons, and be suitable for a wider group of people in NYHA Class III or IV heart failure. It is important to point out that a counterpulsation device is aimed to augment native heart function and is fundamentally different from total artificial hearts, left ventricular assist devices and heart transplants which are meant to be a total replacement or an alternative to the native heart. Thus, the counterpulsation device is considered non-obligatory and not life-supporting. Sunshine Heart, Inc has proposed C-Pulse™, a novel ambulatory, non-obligatory, non-blood contacting extra-ascending aortic counterpulsation system. The C-Pulse™ System is designed to be implanted without the need for cardiopulmonary bypass or extensive dissection, to be able to be activated immediately, to augment heart function in a safe manner and to provide sustained relief from heart failure symptoms. It can be turned off safely, and similarly, in failure modes, is considered to have an associated low risk of death or disability, other than the recurrence of heart failure symptoms. C-Pulse™ is not an alternative to the heart, it is an augmentation device, and it does not preclude the use of therapies that provide full circulatory support such as heart transplantation or LVADs. The C-Pulse™ System consists of a counterpulsation Cuff secured around the outside of the ascending aorta, the main blood vessel out of the heart. The Cuff and a heart signal sensing wire are attached to an external driver. The external Driver inflates and deflates the Cuff in sequence with the ECG signal to assist heart function and improve the pumping capacity of the heart. The Cuff deflects the aorta in a "thumb-printing" manner which has been optimized to minimize aortic wall strain and maximize blood volume displacement per beat. The C-Pulse™ System is non-blood contacting, simple to insert, and can be turned on and off as required; all natural blood pathways are maintained - there is no exposure of foreign material to the bloodstream.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
21
Implantation and activation of counterpulsation therapy for the full duration of the study period. The device may be turned off briefly for personal hygiene, etc.
University of Alabama at Birmingham
Birmingham, Alabama, United States
University of Louisville
Louisville, Kentucky, United States
St. Paul Heart Clinic
Saint Paul, Minnesota, United States
Mid America Heart Institute-Saint Luke's Hospital
Kansas City, Missouri, United States
Number of Surviving Participants That Completed the Study
Amount of participants that did not exit study for reasons including worsening heart failure resulting in hospitalization, LVAD implantation, study withdrawal or death.
Time frame: 5 Years
Six Minute Walk Test
6MWT in distance (meters).
Time frame: 6 Months
Cardiopulmonary Exercise Testing
CPX is performed on a treadmill and carried out to a symptomatic maximum. Minute oxygen consumption (VO2; ml/min) and minute carbon dioxide production (VCO2; ml/min) are measured using a breath-by-breath respiratory gas analyzer. The Respiratory Exchange Ratio (RER) is calculated as VCO2/VO2. A peak RER of ≥1.10 is generally considered an indication of excellent subject effort during CPX. Achievement of a peak RER \<1.00 in a CPX that is terminated by subject request, absent any electrocardiographic or hemodynamic abnormalities, generally reflects submaximal cardiovascular effort.
Time frame: 6 Months
Kansas City Cardiomyopathy Questionnaire (KCCQ)
Overall KCCQ score, a 23-item self-administered questionnaire developed to independently measure the patient's perception of their health status, which includes heart failure symptoms, impact on physical and social function, and how their heart failure impacts their quality of life (QOL) within a 2-week recall period. Scores range from 0-100, in which higher scores reflect better health status.The KCCQ instrument may be used by medical device companies and sponsor-investigators for evaluation of safety and effectiveness for heart failure medical devices to support regulatory submissions. The KCCQ instrument, specifically the Symptom Domain Score, Physical Limitation Domain Score, Social Limitation Domain Score, Quality of Life Domain Score and Overall Summary Score, can be used as a component of a composite primary endpoint or secondary endpoint in a feasibility or pivotal clinical trial evaluating heart failure medical devices.
Time frame: 6 Months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Ohio State University
Columbus, Ohio, United States
Penn State Milton S. Hershey Medical Center
Hershey, Pennsylvania, United States
New York Heart Association (NYHA) Classification
The most commonly used heart failure classification system, the NYHA Functional Classification, classifies patients' heart failure according to the severity of their symptoms. It places patients in one of four categories based on how much they are limited during physical activity (I: No limitation of physical activity, II: Slight limitation of physical activity and comfortable at rest, III: Marked limitation of physical activity and comfortable at rest, IV: Unable to carry on any physical activity without discomfort, and symptoms of heart failure at rest).
Time frame: 6 Months