The main purpose of this study is to get more information on using BMS747158 (the study drug),a drug with small amounts of radioactivity to allow for heart imaging, during a PET scan which can then be compared to other images such as SPECT. The safety and quality of images will be studied.
The primary objectives of this study are: * To acquire data for the development of one-day rest/stress cardiac PET perfusion imaging protocols for BMS747158 with comparable diagnostic image quality to a two-day rest/stress PET protocol * To assess the safety of multiple doses of BMS747158 The secondary objectives of this study are: * To assess PET imaging parameters and image quality following administration of BMS747158 at rest and at stress (pharmacologic or exercise) same day (at different time intervals) and 16-48 hours after the rest injection * To assess feasibility of gated cardiac PET imaging with BMS747158 for left ventricular function assessment * To assess agreement of one and two day rest/stress PET imaging with BMS747158 in patients with reversible ischemia with rest/stress single photon emission computed tomography (SPECT) imaging * To perform a preliminary assessment of the diagnostic accuracy of one-day and two-day rest/stress PET perfusion imaging with BMS747158 as compared with invasive coronary angiography or computed tomography angiography (CTA) for detection of
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
176
dosages at rest and at stress were not to exceed a total of 14 mCi. Cohort 1: Patients received either 2 or 3 IV bolus injections of BMS747158: 1 at rest and 1 or 2 during stress, over a 1-day or 2-day period. Cohort 2: Patients to recieve IV bolus injections of BMS747158: For the Pharmacologic (Adenosine) Stress: * Doses at rest were to range between 2.9 and 3.4 mCi. * Doses under stress were to be a factor of 2.0 to 2.4 greater than the rest dose, resulting in a range of stress doses between 5.8 and 8.2 mCi. For the Exercise Stress: * Doses at rest were to range between 1.7 and 2.0 mCi. * Doses under stress were to be a factor of 3.0 to 3.6 greater than the rest dose, resulting in a range between 5.1 and 7.2 mCi.
Silicon Valley Medical Imaging
Fremont, California, United States
Cohort 1: Determination of Rest Dose: Dose Acquistion Time Product
The rest flurpiridaz dose to be used for subsequent efficacy studies was determined by a modeling method that simulated a range of injected doses using a single fixed injected dose at rest in each subject and a range of acquisition durations. From this, a dose acquisition time product (DATP was determined for each subject that specified the minimal dose for a given acquisition duration that yielded an image in that subject that was negligibly affected by photon counting statistics. Descriptive statistics were used to identify an appropriate rest dose for the population. No other statistical tests were performed
Time frame: Dosing visit
Cohort 2: Diagnostic Efficacy of One-day Rest/Stress BMS747158 PET MPI Sensitivity (SN) vs SPECT MPI Sensitivity
Diagnostic efficacy of one-day rest/stress BMS747158 PET MPI is measured by sensitivity as compared to single photon emission computed tomography (SPECT)MPI in the detection of coronary artery disease (CAD)using angiography or three-month cardiac events as the truth standard.
Time frame: Dosing visit
Cohort 1: Determination of Ratio of Stress Dose to Rest Dose
The stress flurpiridaz dose for subsequent same-day rest-stress efficacy studies was determined as a multiple of the rest dose by computer modeling. Images derived only from rest flurpiridaz administration were blended using image analysis with images derived only from administration of flurpiridaz following exercise or adenosine stress. The blending fraction that resulted in negligible change in reader interpretation of defect severity was determined for each subject. The minimum value that met this criterion for all subjects was used to calculate the ratio of the stress dose to the rest dose as a function of the delay between administration of the two doses for both adenosine stress and exercise stress separately. No statistical analysis was performed.
Time frame: Dosing visit
Cohort 2: Diagnostic Efficacy of One-day Rest/Stress BMS747158 PET MPI Specificity (SP) vs SPECT MPI Specificity
Diagnostic efficacy of one-day rest/stress BMS747158 PET MPI is measured by specificity as compared to single photon emission computed tomography (SPECT)MPI in the detection of coronary artery disease (CAD)using angiography or three-month cardiac events as the truth standard.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Scripps Memorial Hospital
La Jolla, California, United States
Cedars-Sinai Medical Center
Los Angeles, California, United States
UCLA Medical Plaza
Los Angeles, California, United States
Radiological Associates of Sacramento
Sacramento, California, United States
VA Healthcare System San Diego
San Diego, California, United States
Hartford Hospital
Hartford, Connecticut, United States
Yale University
New Haven, Connecticut, United States
Emory University Hospital
Atlanta, Georgia, United States
Primary Care Cardiology Research, Inc
Ayer, Massachusetts, United States
...and 14 more locations
Time frame: Dosing Visit