The purpose of this study is to evaluate the effect of a modified Prep and procedure on colon cleansing level and capsule excretion rate.
The evaluation of subjects with suspected colonic disease includes endoscopic imaging by colonoscopy and radiologic imaging such as air-contrast barium enema, or CT colonography . The Given® Diagnostic System offers an alternative approach for endoscopic visualization of the colon using capsule endoscopy, an ingestible device which contains imagers, light sources, a power source and a RF transmitter. Advantages of the Given® Diagnostic System include the elimination of the need for sedation, the minimally invasive, painless nature of the exam, and the ability to pursue normal daily activities immediately following the procedure . Furthermore, compared to standard colonoscopy, the Given® Diagnostic System may be more readily accepted by the subjects, thereby improving subjects' willingness to undergo a diagnostic evaluation of the colon and comply with colorectal cancer screening recommendations. The PillCam™ SB capsule (formerly M2A® Capsule) that was FDA-approved in August 2001 for small bowel evaluation has been ingested to date by more than 500,000 people worldwide and is well accepted by patients and physicians as well as the processional societies. However, adequate visualization of the colon cannot be achieved with the standard PillCam™ SB capsule because of the anatomical and physiological properties of the colon which are significantly different than the small bowel. Moreover, other issues that limit the evaluation of the colonic mucosa by the standard PillCam™ SB procedure include an unsatisfactory level of colon cleanliness and slow progression of the PillCam™ SB capsule through the colon during the desired examination time. Therefore, the development and introduction of a specially designed, customized colon capsule combined with a dedicated capsule colonoscopy procedure protocol will allow for more efficient evaluation of the colonic mucosa. This is expected to improve the capability of the Given® Diagnostic System to detect colonic pathologies and to serve as a diagnostic and screening tool for colonic disease. Further details of the PillCam™ Colon Capsule Endoscope (PCCE) can be found in the device description section. This is a pilot study that is designed to compare the levels of cleanliness and visualization of colon achieved by colon capsule endoscopy when using different regimens for preparation of the colon. Furthermore, capsule colonoscopy and colonoscopy procedures will be compared in regards to the level of colon cleanliness and detection of lesions in the colon.
Study Type
OBSERVATIONAL
Enrollment
127
Hospital del Mar
Barcelona, Spain
Hospital Clinic i Provincial
Barcelona, Spain
Hospital Georio Maranon
Madrid, Spain
Hospital Clinico San Carlos
Madrid, Spain
Hospital virgen Macarena
Colon cleansing level score
Time frame: within 7 days
Number of colon capsules excreted over time
Time frame: within 7 days
Accuracy parameters of PCCE, compared to colonoscopy.
Time frame: within 7 days
Diagnostic yield of PCCE compared to standard colonoscopy
Time frame: within 7 days
Number of complete capsule procedure
Time frame: within 7 days