Total intra-venous anesthesia can be provided using a closed-loop system guided by the bispectral index. The purpose of this study is to determine if myorelaxation modifies its functioning.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
140
muscle relaxant administration throughout anesthesia
no muscle relaxant throughout anesthesia (normal saline infused as a placebo)
CHU Besançon
Besançon, France
Institut Paoli-Calmette
Marseille, France
Hôpital Foch
Suresnes, France
propofol dose
Time frame: one hour anesthesia
remifentanil dose
Time frame: one hour anesthesia
number of automatic modifications of the propofol and remifentanil concentrations
Time frame: one hour anesthesia
number of patients' movements
Time frame: one hour anesthesia
number of hemodynamic abnormalities requiring treatment
Time frame: one hour anesthesia
time to wake up
Time frame: end of anesthesia
intraoperative awareness
Time frame: postoperative day 1 or 2
performance of the closed-loop system
Time frame: one hour anesthesia