This study will compare the amount of bronchial tube relaxation from the Formoterol medicine contained in the Symbicort pressure Metered Dose Inhaler(pMDI)(a combination of Budesonide, a steroid, and Formoterol, a drug which relaxes the bronchial smooth muscle. The comparison will be using the pMDI in the usual fashion to the pMDIs and a spacer which allows more time for breathing in the medication. Breathing tests will be measured over a 12 hour period for the comparison.
Sixteen subjects will receive treatment in a cross-over design. They will inhale Symbicort 160/4.5 two inhalations in the manner prescribed in the approved package insert. The second intervention will be the inhalation of Symbicort 160/4.5 two inhalations through a valved holding chamber (Aero Chamber Plus). Breathing tests including spirometry will be measured at various time periods over a 12-hour time frame in each intervention. Comparison will be made of the two periods to demonstrate that the use of the valved holding chamber does not adversely affect the bronchodilation of the formoterol component of the combination drug.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
OTHER
Masking
NONE
Enrollment
16
The asthmatic subjects will receive budesonide/formoterol pMDI 160/4.5 pMDI 2 inhalations used in conventional fashion, and have pulmonary function measured over 12 hours who are expected to show bronchodilation.
Symbicort 160/4.5 2 inhalations will be administered through a valved holding chamber, Aerochamber Plus, Pulmonary functions will be measured over 12 hours in asthmatic subjects who are expected to show bronchodilation.
Western Sky Medical Research
El Paso, Texas, United States
The Mean Area Under the Curve (AUC) of Forced Expiratory Volume in One Second (FEV-1) Over 12 Hours, Measured (BL), 5, 10, 15, 60, 120, 240, 480, 720 Minutes. The Unit is Liters, and the AUC is in Liters.
The mean FEV-1 (Forced Expiratory Volume 1 second) for each of the treatments (with and without valved holding chamber) in this crossover design were recorded at BL, 5, 10, 15, 30, 60, 120, 240. 480, 720 minutes (12 hrs) were plotted as a curve and the area under the curve was calculated. The measured results was mean liters/12 hours.
Time frame: BL, 5, 10,15,30,60,120,240,480,720 minutes (12 hrs)
FEV-1/FVC
The ratio of the volumes in liters of FEV-1 to Forced vital capacity (FVC). This is reported as percent for each time point., Each time point will be compared.for the two interventions. This expressed as a percentage.
Time frame: 0,5,10,15,30,60,120,240,480,720 minutes