The purpose of this study is to determine how well perfusion cardiac magnetic resonance (MR) imaging is able to detect certain heart abnormalities, such as a coronary artery narrowing. To this purpose, a conventional MR contrast medium (Gd-DTPA-BMA) will be used during an adenosine infusion (an approved substance which enlarges the arteries of the heart, so that the blood flow to the heart muscle increases). This magnetic resonance imaging technique will be compared with single photon emission computed tomography (SPECT), a well-established technique to detect this heart abnormalities. Both, cardiac MR and SPECT will be compared with invasive coronary angiography, a technique which directly visualized the heart vessels and narrowings of these (=standard of reference).
This study is a multicentre, open label, phase III study in adult subjects designed to show that Gd-DTPA-BMA (a conventional MR contrast medium = OMNISCAN) enhanced myocardial MR perfusion imaging is non-inferior to myocardial SPECT. Both imaging techniques will be performed during adenosine stress (0.14mg/min/kg over 3 minutes IV). Gd-DTPA-BMA will be used twice (2 doses of 0.075 mmol/kg for the stress and rest study each) for the detection of myocardial perfusion defects. The standard of reference is invasive coronary angiography, which defines the presence of coronary artery disease, if vessels of at least 2mm in diameter show stenosis of at least 50% (diameter reduction). Patients with a history of myocardial infarction(s) are positive for coronary artery disease, even when coronary arteries are not stenosed as evidenced by the coronary angiography performed in the setting of this trial(= assigning patients as positive for coronary artery disease after successful PCI-revascularization of acute infarct(s) in the past).
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
533
Perfusion CMR is performed during adenosine infusion for vasodilation (3 minutes of 0.14mg/kg/min IV) and injection of Gd-DTPA-BMA at 0.075mmol/kg IV.
Perfusion CMR with Gd-DTPA-BMA to detect coronary artery disease
Non-inferiority of perfusion CMR vs SPECT for sensitivity and specificity (binary reading) for the detection of coronary artery disease
Time frame: SPECT and invasive angiography are performed within 4 weeks before or after CMR
Assessment of the diagnostic performance of CMR and SPECT expressed as area under the receiver operator characteristics curve to detect coronary artery disease
Time frame: SPECT and invasive angiography are performed within 4 weeks before or after CMR