The investigators' hypothesis is that placement of CollatampG in the subcutaneous layer of contaminated abdominal wounds is effective prophylaxis for superficial surgical site infection (SSI). CollatampG is composed of highly purified type 1 collagen obtained from bovine tendon, which acts as a vehicle for the aminoglycoside antibiotic, gentamicin. This implant provides a high concentration of local gentamicin at the surgical wound to decrease the local microorganism load. It has been shown that if a surgical site is contaminated with \> 10 to the power of 5 microorganisms per gram of tissue, the risk of infection is markedly increased. When a gastrointestinal organ is the source of pathogens, gram-negative bacilli (e.g., E. coli) are typical isolates, which are susceptible to gentamicin. Therefore, a high local concentration of gentamicin at the contaminated surgical wound provided by the CollatampG implant may prevent the local bacterial load from reaching levels high enough to cause a clinical infection.
Aims: To decrease the incidence of superficial surgical site infection (SSI) using a collagen -gentamicin implant (CollatampG) for patients who undergo major abdominal surgery with contaminated surgical wounds. Hypotheses: Patients undergoing abdominal surgery with wounds classified as contaminated or dirty are at a high risk of SSI. Wounds are classified as contaminated when an operation is performed through an infected area (e.g abscess, perforated viscus or traumatic wound) that has been exposed for over 4 hours. Risk of infection in these wounds has been shown to be as high as 45 %. Our hypothesis is that placement of CollatampG in the subcutaneous layer of contaminated abdominal wounds is effective prophylaxis for superficial SSI. CollatampG is composed of highly purified type 1 collagen obtained from bovine tendon, which acts as a vehicle for the aminoglycoside antibiotic, gentamicin. This implant provides a high concentration of local gentamicin at the surgical wound to decrease the local microorganism load. It has been shown that if a surgical site is contaminated with \>10 to the power of 5 microorganisms per gram of tissue, the risk of infection is markedly increased. When a gastrointestinal organ is the source of pathogens, gram-negative bacilli (e.g., E. coli) are typical isolates, which are susceptible to gentamicin. Therefore, a high local concentration of gentamicin at the contaminated surgical wound provided by the CollatampG implant may prevent the local bacterial load from reaching levels high enough to cause a clinical infection.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
PREVENTION
Masking
DOUBLE
Enrollment
70
Collatamp Gentamicin placed into subcutaneous layer of dirty abdominal wounds
Singapore General Hospital
Singapore, Singapore
Incidence of superficial surgical site infections
Time frame: 30 days
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.