Less than 20% of patients with malignant distal bile duct (BD) obstruction (often pancreatic cancer) are suitable for resection surgery.In the rest,palliation treatment comes into focus. Jaundice caused by BD obstruction gives pain, infection (cholangitis), often itching and increased weight loss, and the patient is stigmatized by the deep yellow colour of the skin.Therefore palliation with endoscopic stenting by ERCP-technique is important. Modern self-expanding metal stents (SEMS) are now widely used in this context. Comparison in a RCT between steel and nitinol SEMS has never been performed. The steel stent (Wallstent®) is the "original",is widely used, and has more expanding power. Nitinol stents are softer and claimed to be easier to insert,and are more and more popular.A newly developed nitinol stent (Wallflex®)may have these advantages, but is some 120 Euros more expensive. Regarding the most important outcome measure, time to stent failure (obstruction), no one knows if there is any difference.Our hypothesis is that there is no difference in this main outcome endpoint.
Secondary outcome measures (compare above) are complications caused by the stent or stent insertion and technical ease to insert the stent. To discover a 12% difference between the 2 groups, regarding patency, 400 patients must be included in the trial, alfa 0.05, beta 0.8. Investigators know from previous trials (Single center trial South Hospital GIE 2006;63:986-995 and a newly finished similar swedish multicenter trial,prel data DDW- 09)that the 9 hospitals recruited will be able to include this no of patients in approximately 2.5 years. Investigators will have a shortest follow-up period of 10 months, followup will be by phone with standard questions connected to stent failure, which is defined clinically AND by a new ERCP with intervention because of an obstructed stent.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
400
Department of Surgery, Upper GI Div. South Hospital,
Stockholm, SLL, Sweden
Sahlgrenska Universitetssjukhuset
Gothenburg, Sweden
Länssjukhuset Ryhov
Jönköping, Sweden
Länssjukhuset i Kalmar
Kalmar, Sweden
Blekingesjukhuset
Karlskrona, Sweden
Centralsjukhuset i Kristianstad
Kristianstad, Sweden
Universitetssjukhuset i Lund
Lund, Sweden
Universitetssjukhuset i Malmö,
Malmo, Sweden
dept surgery, South Hospital-Karolinska Institute
Stockholm, Sweden
Claes.Soderlund
Stockholm, Sweden
...and 1 more locations
confirmed stent failure
Time frame: 300 days follow up
safety with respective stent in trial at insertion and afterwards(complic.)
Time frame: 300 days
Survival
Survival difference between two groups
Time frame: 300 days