The purpose of the study is to evaluate diagnostic performance of high iodine (iopamidol 370 mg/dl) content versus low iodine (iodixanol 300 mg/dl) content for diagnostic accuracy by contrast-enhanced Coronary Cardiac Computed Tomography (CCTA) using a 64-detector-row CT scanner for detection of presence or absence of coronary artery obstruction when compared against invasive coronary angiography, the standard of truth.
Coronary Cardiac CT (CCTA) is a widely accepted modality for non-invasive evaluation of coronary atherosclerosis. The diagnostic performance of CCTA for detecting coronary artery plaque burden has been validated in numerous studies, reaching a negative predictive value of 99%. The current gold standard for anatomic coronary imaging is Invasive Coronary Angiography (ICA) which portends a small but significant procedural-related complication of 1.7%. Non-invasive coronary imaging has the potential to replace ICA but the variability in diagnostic performance of CCTA remains under study. Among the potential variables causing differences in diagnostic performance is perhaps the degree of opacification of coronary artery by iodinated contrast. While numerous contrast agents exist, those that provide improved low and high contrast resolution (for delineating plaque from arterial wall and lumen from plaque, respectively) are hypothetically, the most optimal agents. To date, however, this has not been well evaluated. Further, use of a contrast agent which maximizes patient comfort is desired, as this may reduce heart rate increases and heart rate variability, which may in turn improve diagnostic image quality of CCTA. We hypothesize that the use of lower iodine content iso-osmolar agent - iodixanol - will improve diagnostic performance and patient comfort, as compared to higher iodine content low osmolar iodinated contrast - iopamidol.
Study Type
OBSERVATIONAL
Enrollment
250
Capital Cardiology Associates
Albany, New York, United States
Hudson Valley Heart Center
Poughkeepsie, New York, United States
University of British Columbia
Vancouver, British Columbia, Canada
Diagnostic accuracy for coronary artery stenosis detection at the per-segment, per-vessel and per-patient level using an 18-coronary artery segment model as defined by Society of Cardiovascular Computed Tomography (SCCT), as compared to ICA.
Time frame: 72 hours
Heart rate increase and variability during contrast injection. Rates of 7-day contrast-induced nephropathy. Any untoward adverse reactions like flushing, itching, nausea/vomiting etc
Time frame: 7 days
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.