The purpose of this study is to evaluate the effect of an investigational silicone hydrogel soft contact lens on new contact lens wearers (neophytes) compared to a control of spectacle wearers.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
157
spectacle wearers
Ohio State University
Columbus, Ohio, United States
Papillary Conjunctivitis
Swelling of the papillary (Papillary conjunctivitis) area of the eye was assessed using a slit-lamp. Comparison between the two study arms will be assessed using data generated from a slit-lamp examination, using an Efron scale with 0.1 unit increments. The Efron scale has a range of 0 (normal) to 4 (Severe) and is subjectively assessed for 0.1 increments by the clinician, with the higher the magnitude of the number the worse the score.
Time frame: 1 Year
Conjunctival Hyperemia
Comparison of the amount of redness in the conjunctival area of the eye, between the two study arms will be assessed using data generated from a slit-lamp examination, using an Efron scale with 0.1 unit increments. The Efron scale has a range of 0 (normal) to 4 (Severe) and is subjectively assessed for 0.1 increments by the clinician, with the higher the magnitude of the number the worse the score.
Time frame: 1 Year
Limbal Hyperemia
Swelling of the vessels in the limbal area of the eye using a slit lamp. Comparison between the two study arms will be assessed using data generated from a slit-lamp examination, using an Efron scale with 0.1 unit increments. The Efron scale has a range of 0 (normal) to 4 (Severe) and is subjectively assessed for 0.1 increments by the clinician, with the higher the magnitude of the number the worse the score.
Time frame: 1 Year
Corneal Staining
Abrasions in the cornea area of the eye using a slit lamp. Comparison between the two study arms will be assessed using data generated from a slit-lamp examination, using an Efron scale with 0.1 unit increments.
Time frame: 1 Year
Conjunctival Staining
Mild abrasions of the conjunctival area of the eye. Comparison between the two study arms will be assessed using data generated from a slit-lamp examination, using an Efron scale with 0.1 unit increments. The Efron scale has a range of 0 (normal) to 4 (Severe) and is subjectively assessed for 0.1 increments by the clinician, with the higher the magnitude of the number the worse the score.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Time frame: 1 Year
Corneal Neovascularization
New vascularization of the Cornea. Comparison between the two study arms will be assessed using data generated from a slit-lamp examination, using an Efron scale with 0.1 unit increments. The Efron scale has a range of 0 (normal) to 4 (Severe) and is subjectively assessed for 0.1 increments by the clinician, with the higher the magnitude of the number the worse the score.
Time frame: 1 Year
Differences in Subjective Comfort From the Contact Lens User Experience (CLUE) Questionnaire
The subjective comfort questionnaire CLUE, assesses the overall lens comfort. The CLUE Questionnaire is a validated patient-reported outcomes questionnaire to assess patient-experience attributes of soft, disposable contact lenses in the US, ages 18-65. Scores follow a normal distribution with a population average score of 60 (SD 20), where higher scores indicate a more favorable/positive response, with a range of 0-120. The differences between: (final visit and first visit) and then (final visit and 6 months) are reported.
Time frame: 1 Year
Comfortable Wearing Time
Average numbers of overall average daily contact lens wear hours and average daily comfortable wear hours as reported at each follow-up visit.
Time frame: 1 Year