The main purpose of this study is to determine whether the surgical time required for primary total knee arthroplasty is significantly less when performed with Customized Patient Instrumentation (CPI) than with conventional instrumentation. Each case will be recorded by video camera, in order to time the length of surgery and each surgical step. The number of surgical trays required for each case will be recorded. As an additional endpoint, the investigators will measure limb and component alignment on x-rays to determine if these two methods achieve equivalent alignment results. The thickness of bone cuts will be compared to the surgical plan and to each other. The primary hypothesis is that the use of customized patient instrumentation will reduce the operative time required for total knee arthroplasty.
Patient-specific instrumentation (PSI) has been developed for total knee arthroplasty (TKA) with several potential advantages over traditional instrumentation (TI). Shortened surgical time, fewer surgical instruments, and improved alignment are some of these proposed advantages. We sought to examine these assertions. 52 patients (26 per group) were enrolled in a prospective, randomized trial comparing CT-based PSI with TI. No difference was seen in average patient age (68 years) or BMI (31) between groups (p=0.84 and p=0.89), although there were more males in the PSI group (14 vs 7, p=0.002). A single surgeon and consistent staff performed the surgeries with the same knee prostheses, and all cases were videotaped to measure the length of surgery and each individual step. Any additional bone cuts, size changes, or ligament releases made to achieve correct alignment and balance were documented. The number of instrument trays opened for each case was recorded. Postoperative long alignment and lateral radiographs were taken to measure the coronal and sagittal plane component alignment and mechanical axis in each patient.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
70
Custom cutting guides based on computed tomography (CT) images of the patient's leg are used to make the bone cuts and select the implant size.
Traditional surgical instruments will be used to make bone cuts and size the components in this control group.
Anderson Orthopaedic Research Institute
Alexandria, Virginia, United States
Length of Surgery
Time elapsed from skin incision to wound closure (in seconds)
Time frame: 1 day
Length of Each Surgical Step (in Seconds)
surgical exposure, tibial alignment and resection, femoral distal cut, extension gap balancing, sizing the femur, 4 finishing femoral cuts, posterior releases, patellar resection, trial components, tibial tray preparation, cleanup/ prep for cement, cementing femur, cementing tibia, cementing patella, and closure
Time frame: 1 day
Number of Instrument Trays Required
Time frame: 1 day
Limb Alignment (Mechanical Axis)
Alignment is measured on 4 month postoperative radiograph in degrees. The goal is a mechanical axis between and femur and tibia of 0 degrees. Varus alignment ("bow-legged") is shown as a negative number in degrees away from 0. Valgus alignment ("Knock-kneed") is expressed as a positive number in degrees away from 0.
Time frame: 4 months