The overall research plan is to test the hypothesis that intraoperative treatment of hyperinsulinemic normoglycemic clamp (HNC) in cardiac surgical patients improves myocardial function and short-term outcomes compared with standard glucose management.
Specific Aim #1:To determine whether intraoperative use of HNC affords cardioprotective benefits measured by improved echocardiographic measures of myocardial function, serum markers of cardiomyocyte injury, and hemodynamic indices measured immediately (at end of surgery) and during the short-term (initial hospitalization).
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
DOUBLE
Enrollment
100
Prior to anesthetic induction, a baseline blood glucose value will be obtained, followed by an insulin infusion of 5 mU.Kg-1.min-1. When blood glucose is \<110 mg/dL, a variable continuous infusion of glucose (dextrose 20%) supplemented with potassium (40 mEq/L) and phosphate (30 mmol/L) is administered to preserve normoglycemia (80-110 mg/dL). The glucose infusion is titrated to target glucose levels by checking blood glucose every 5 - 15 min with Accu-Check (Roche Diagnostics, Switzerland) glucose monitor. At sternal closure, insulin infusion is decreased to 1 mU/Kg/min. On admission to the ICU, insulin treatment follows the ICU protocol. The dextrose infusion is slowly weaned off over 2 - 4 hrs maintaining blood glucose \> 80 mg/dL. Arterial blood glucose is measured every 30 - 60 min for 2 hrs, then, as stated in ICU protocol.
Baseline arterial blood glucose will be obtained before anesthetic induction. Repeat measurements are performed every 30-90 min. Glucose \>150 on CPB will receive insulin according to intraoperative protocol. After surgery, insulin is given according to ICU protocol. Target glucose \< 180 mg/dL.
Cleveland Clinic Foundation
Cleveland, Ohio, United States
Myocardial Function: Left Ventricular Global Longitudinal Strain (%)
Left ventricular global longitudinal strain measured by intraoperative transesophageal echocardiography at end of surgery and assessed using off-line speckle-tracking echocardiography. higher values (%) mean a worse outcome.
Time frame: end of surgery (closure), an average of 5 minutes
Intraoperative Left Ventricular (LV) Global Longitudinal Strain Rate
Left ventricular global longitudinal strain rate measured by intraoperative transesophageal echocardiography at end of surgery and assessed using off-line speckle-tracking echocardiography. higher values mean a worse outcome
Time frame: end of surgery (closure) an average of 5 minutes
Intraoperative Right Ventricular (RV) Systolic Longitudinal Strain
Right ventricular global longitudinal strain measured by intraoperative transesophageal echocardiography at end of surgery and assessed using off-line speckle-tracking echocardiography. higher values mean a worse outcome.
Time frame: end of surgery (closure) an average of 5 minutes
Intraoperative Right Ventricular (RV) Systolic Longitudinal Strain Rate
Right ventricular global longitudinal strain rate measured by intraoperative transesophageal echocardiography at end of surgery and assessed using off-line speckle-tracking echocardiography. higher values mean a worse outcome
Time frame: end of surgery (closure) an average of 5 minutes