The purpose of this study was to compare objective clinical measures of visual performance and subjective measures of satisfaction and preference between standard progressive addition lens (PAL) spectacles and a new type of free-form surfaced, optically customized PAL spectacle.
In a double-masked crossover trial, 95 experienced wearers wore customized free-form PAL spectacles (Test) and standard non-free-form PAL spectacles (Control) for one week each. All subjects wore both Test and Control spectacles, and the pair to be worn first was randomly assigned. At dispensing and after 1 week of wear, subjects were tested for distance and near visual acuity (VA) under both high and low contrast; in addition, 30 degree off-axis VA was measured using a novel apparatus, as was the horizontal extent of undistorted vision at reading distance. Subjects also completed a set of questionnaires detailing their satisfaction levels, adaptation times, and preferences for Test or Control spectacles for different visual tasks.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
DOUBLE
Enrollment
95
Control spectacles include several different PAL brands as selected by patients in the UC Berkeley Optometry Clinic and purchased in the Eyewear Center; after successful fitting and purchase, potential subjects were recruited for the trial.
Test spectacles are Zeiss Individual, free-form surfaced, and customized using the iTerminal device to account for individual back vertex distance, wrap angle and pantoscopic tilt
Clinical Research Center, School of Optometry, University of California, Berkeley
Berkeley, California, United States
Visual Acuity, High Contrast, Distance Chart
Standard assessment of high contrast visual acuity at distance, as in normal clinical practice, using Baily-Lovey charts and the M\&S Technologies Smart System II visual acuity projection system.
Time frame: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
Visual Acuity, Low Contrast, Distance Chart
Standard assessment of low contrast visual acuity at distance, as in normal clinical practice, using Baily-Lovey charts and the M\&S Technologies Smart System II visual acuity projection system.
Time frame: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
Visual Acuity, High Contrast, Near Chart
Standard assessment of high contrast visual acuity at near, as in normal clinical practice, using Baily-Lovey charts and the M\&S Technologies Smart System II visual acuity projection system.
Time frame: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
Visual Acuity, Low Contrast, Near Chart
Standard assessment of low contrast visual acuity at near, as in normal clinical practice, using Baily-Lovey charts and the M\&S Technologies Smart System II visual acuity projection system.
Time frame: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
30-degree Off-axis Distance Visual Acuity, High Contrast Chart
Measured with subject immobilized in specially designed apparatus, keeping head pointed straight forward and moving only the eyes to left or right to view the off-axis chart
Time frame: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
30-degree Off-axis Distance Visual Acuity, Low Contrast Chart
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Measured with subject immobilized in specially designed apparatus, keeping head pointed straight forward and moving only the eyes to left or right to view the off-axis chart
Time frame: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
Horizontal Extent of Undistorted Vision at Reading Distance
Novel apparatus designed to immobilize head and allow subject to indicate point of peripheral optical distortion on a modified Amsler-type grid
Time frame: Post-1 week of wear of Test Spectacles and post-1 week of wear of Control Spectacles
Questionnaire Battery
Forced-choice Likert scale preference questionnaire
Time frame: At study exit, after both Test and Control spectacles had been worn for 1 week each