The purpose of this study is to demonstrate the (statistical) non-inferiority of iobitridol (Xenetix® 350) when compared to contrast agents with higher iodine concentrations, iopromide (Ultravist® 370) and iomeprol (Iomeron® 400) in terms of coronary CT scan evaluability (quality and interpretability of images).
Patients suspected of coronary artery disease were submitted to coronary CT angiography using either iobitridol or contrast agents with higher iodine concentrations (iopromide or iomeprol). Independent off-site readers evaluated image quality regarding the ability to identify coronary artery stenosis (score 0- non evaluable to 4- excellent quality). The study was aimed at showing the non-inferiority of iobitridol in its ability to provide evaluable CT scans for the identification of coronary stenosis.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
DIAGNOSTIC
Masking
DOUBLE
Enrollment
468
CHU Angers
Angers, France
CHU de la Cavale Blanche
Brest, France
Rate of Patients With Evaluable CT Scans i.e. Allowing Identification of Coronary Artery Stenosis According to Off-site Reading Assessment
Evaluability was based upon the off-site assessment of 18-coronary segments graded for image quality with a 5-point scale.4= Excellent quality, fully confidence without any doubts concerning the presence/absence of luminal stenosis; 3= Good quality, confidence concerning the presence/absence of luminal stenosis; 2= Moderate quality, relative confidence, with minor doubts concerning the presence/absence of luminal stenosis; 1= Poor quality, some doubts concerning the presence/absence of stenosis; 0= Non diagnostic. A patient's CT scan was considered as evaluable for identification of coronary artery stenosis if none of the 18 coronary segments had a score of 0.
Time frame: < 24h
Average Image Quality According to Off-site Reading
For each patient, all 18 coronary segments were graded for image quality using a 5-point evaluation scale (from 0=non-diagnostic to 4=excellent). The average image quality was evaluated using the off-site readings, by averaging the scores obtained for the 18 segments used to determine the CT evaluability (primary criteria).
Time frame: <24h
Coronary Track Rate
A post processing software automatically tracked the number of distal segments of the left anterior descending coronary artery, the left circumflex coronary artery and the right coronary artery . The number of segments tracked per patient were assessed by an independent off-site radiologist.
Time frame: <24h
Average Signal Attenuation After IV Injection of Contrast
Attenuation of signal was measured off-site on post-injection images of four coronary segments, in the ascending aorta and in the left ventricle, then it was averaged at the patient level.
Time frame: <1h
Average Signal-to-Noise Ratio (Average SNR)
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Centre Chirurgical Marie Lannelongue
Le Plessis-Robinson, France
La Timone Adultes
Marseille, France
Hopital Cochin
Paris, France
Haut-Lévêque / Radiologie
Pessac, France
CHU Pontchaillou
Rennes, France
CHU Rouen - Hopital Charles Nicolle
Rouen, France
Centre Cardiologique du Nord
Saint-Denis, France
Institut für Radiologie Universitätsklinikum Charité
Berlin, Germany
...and 13 more locations
Signal attenuation was measured by off-site radiologists in the lumen of 4 coronary segments, in the ascending aorta and in the left ventricle and was expressed in Hounsfield Unit (HU). Measurements were set in post-injection images for the 6 territories. A measure of noise in CT scans was collected at least in the aorta and if possible in the muscle and/or air. Signal-to-Noise Ratios (SNR) of post-injection images were derived in all territories from attenuation measurements according to the following formula: SNR Territory = Post Attenuation / Image Noise
Time frame: <1h
Average Contrast-to-noise Ratio (Average CNR)
Signal attenuation was measured by off-site radiologists in the lumen of 4 coronary segments in the ascending aorta and the in left ventricle and expressed in Hounsfield Unit (HU). A measure of noise in CT scans was collected at least in the aorta and if possible in the muscle and/or air. In territories where pre and post signal attenuation measures were both available, the contrast-to-noise ratio was computed according to the following formula: CNR = (Post Att - Baseline Att) / Image Noise
Time frame: <1h