The objective of this feasibility study is to evaluate the efficacy and safety of automated determined Insulin pump settings (i.e., basal plan, correction factor, carbohydrate ration and insulin activity time) using the MD-Logic Pump Advisor in individuals with type 1 diabetes. Study design: Prospective study with two segments: (i) Pilot study, 30 days trial evaluating the MD-Logic pump advisor and (ii), randomized controlled trial (RCT), 30-78 days trial comparing MD-Logic pump advisor to the standard of care of patients with type 1 diabetes. The RCT will be initiated after the pilot segment (including data analysis). The pilot segment will include 15-30 pediatric patients. In the RCT, up to 105 (50 minors under this protocol and 55 adults under a separate protocol)eligible subjects will be enrolled to allow for 92 valuable subjects at the end of the study. The subject population will be randomly assigned 1:1 to either the intervention group or control group. At this pediatric sub study approximately 50 patients will participate and at the separate Adults study additional 55 adult patients will participate.
the MD-Logic Pump Advisor was design by the Diabetes Technology Center, the Institute of Endocrinology and Diabetes, National Center for Childhood Diabetes, Schneider Children's Medical Center of Israel. The MD-Logic Pump Advisor learns and adapts the patient's insulin pump settings in order to optimize glucose control. The MD-Logic Pump Advisor needs, as input, sensor readings, insulin delivery and recording of the meals during home care. During collection of the data, the patients are asked to continue their daily routine (no need for special consideration). The present study was designed to test the automatic algorithm that will evaluate and change, when necessary, the patient's insulin pump settings based on prior sensor reading, insulin delivery, and meals data that was collected while the patient is under his regular treatment at home. The objective of this feasibility study is to evaluate the efficacy and safety of automated determined Insulin pump settings (i.e., basal plan, correction factor, carbohydrate ration and insulin activity time) using the MD-Logic Pump Advisor in individuals with type 1 diabetes. Study design: Prospective study with two segments: (i) Pilot study, 30-78 days trial evaluating the MD-Logic pump advisor and (ii), randomized controlled trial (RCT), 30-78 days trial comparing MD-Logic pump advisor to the standard of care of patients with type 1 diabetes. The RCT will be initiated after the pilot segment (including data analysis). The pilot segment will include 15-30 pediatric patients. In the RCT segment, up to 105(50 minors under this protocol and 55 adults under a separate protocol) eligible subjects will be enrolled to allow for 92 valuable subjects at the end of the study. The subject population will be randomly assigned 1:1 to either the intervention group or control group. At this pediatric sub study approximately 50 patients will participate and at the separate Adults study additional 55 adult patients will participate.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
25
Insulin pump setting (i.e basal plan, correction factor, carbohydrate ratio and insulin activity time)will be adjusted using the MD-LOgic Pump Advisor
Schneider Children's Medical center
Petah Tikva, Israel
University Children's Hospital
Ljubljana, Slovenia
Time spent in the normal range
increase in the time spent in the normal range, defined as sensor glucose level within 70-180 mg/dl
Time frame: Day 40
Number of iterations required to achieve the maximal time spent in the normal range
number of iterations required to achieve the maximal time spent in the normal range
Time frame: day 40
Time spent above glucose level of 180 mg/dl
time spent above glucose level of 180 mg/dl
Time frame: day 40
Time spent below glucose level of 70 mg/dl
time spent below glucose level of 70 mg/dl
Time frame: day 40
Number of hypoglycemic events below glucose value of 63 mg/dl
Number of hypoglycemic events below glucose value of 63 mg/dl
Time frame: day 40
Adverse event
adverse event
Time frame: day 40
Glucose variability
glucose variability
Time frame: day 40
Quality of life questionaire
quality of life questionaire
Time frame: day 40
Number of recommendations the physician would not institute
number of MD Logic Pump Advisor recommendations the physician would not institute
Time frame: day 40
Number of recommendations for changes in setting per patient and per iPRO wear
Number of recommendations for changes in setting per patient and per iPRO wear
Time frame: day 40