The primary purpose of this study is to demonstrate that the BD 4mm x 32G Ultra-Fine Nano pen needle provides equivalent glycemic control to the BD 8mm x 31G Ultra-Fine short pen needle as measured by fructosamine (FRU) among Lantus®, Levemir®, and/or NPH users taking one or more single daily injections of greater than 40 units of insulin. Glycemic control, injection pain, leakage, preference, comfort, and other parameters will be compared between the 4mm x 32G and the 8 mm x 31 G pen needle after three weeks of use of each device. Sufficient numbers of subjects taking Lantus® as their basal insulin will be enrolled so as to allow for pre-specified analysis of this subgroup.
This is an open-label, randomized two period crossover study. Each subject's participation is expected to last about seven weeks and includes a brief enrolment period followed by two consecutive three week treatment periods (Period 1 and Period 2). In Period 1, subjects will use the first assigned study pen needle (either the 4mm Nano or the 8mm Short) to self-administer daily all their pen-based diabetes medications. Upon completion of Period 1, subjects will switch to the alternate pen needle for Period 2. The randomization schedule will determine the order of pen needle use. Blood samples for determination of fasting blood glucose and serum fructosamine concentrations will be collected at baseline (Visit 2) and the end of Period 1 (Visit 3) and Period 2 (Visit 4). Blood samples will be analyzed by a central laboratory.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
OTHER
Masking
NONE
Enrollment
21
The pen needle will be used to administer all pen-based diabetes medications. When using the 4mm Nano pen needle, subjects are directed to hold the pen device at a 90 degree angle and perform the injection with no pinch-up.
The pen needle will be used to administer all pen-based diabetes medications. When using the 8mm Short pen needle, subjects are directed to use the pinch-up technique for injections in the abdomen and thigh, and no pinch-up at other injection sites. Subjects are to hold the pen device at a 90 degree angle.
International Diabetes Center (IDC)
Minneapolis, Minnesota, United States
Comprehensive Clinical Research
Berlin, New Jersey, United States
BioPharma Services Inc.
Toronto, Ontario, Canada
Glycemic Control as Measured by Percent (%) Absolute Change in Fructosamine
The measure of glycemic control will be the percent difference in FRU assessed at the end of Period 1 compared to FRU assessed at the end of Period 2. The average percent difference in FRU between the Nano and Short pen needles, with the Short as a reference, must be shown to be no more than +/- 20% with 95% confidence. General linear models will be used, adjusting for baseline FRU. This outcome measure was to be determined for the total subject population as well as for the subset of Lantus users.
Time frame: 3 weeks per pen needle