Study hypothesis: a new, low polymerization stress flowable composite performs no differently to a conventional, highly filled composite filling material when used as a restorative in small cavities in back teeth. Study will evaluate the clinical performance of a low shrinking flowable composite filling material, compared with a conventional, highly filled composite restorative when used to permanently fill small cavities in molar and premolar teeth in adult patients.
The study will evaluate clinical performance of a low shrink flowable composite filling material and compare it with a conventional, highly filled composite. The study materials will be used to restore small cavities in molar and premolar teeth in adult patients.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
60
Restoration of small Class V and I cavities in molar and premolar teeth
Restoration of small Class V and I cavities in molar and premolar teeth
University of Alabama at Birmingham School of Dentistry, 605 School of Dentistry Building, 1919 7th Avenue South
Birmingham, Alabama, United States
Clinical Performance by Cvar & Ryge Scores
Clinical performance reported on 6 parameters as the % of teeth with perfect scores ("A" rating). Cvar \& Ryge scores measure 6 parameters: Anatomic form (rated A,B= satisfactory, C=unsatisfactory); Color Match (A=match, B=mismatch, but within normal, C=mismatch outside normal); Marginal Adaptation (A=no visible crevice, B=no exposure of dentin, C=defect to enamel-dentine junction, D= fracture, missing); Marginal Discoloration (A=none, B= marginal discoloration, C=marginal discoloration to pulpal direction); Surface Integrity (A=smooth, B=slight rough, C=Pitted, D=fracture)'Secondary caries (A=none, D=present).
Time frame: baseline, 6, 12 and 24 months
Clinical Performance by VAS (Pain Scale)
Sensitivity to cold was measured by applying a cotton pellet soaked with pulp vitality refrigerant spray (Endo Ice, Coltene/ Whaledent, Cuyahoga Falls, OH, USA) to the tooth for three seconds. Sensitivity to biting was measured by having the patient bite on a cotton roll for five seconds. After each test, the subject was asked to place an ''X'' on a 10-mm line labeled ''1'' on the left and ''10'' on the right. Patients were told that a ''10'' represents the worst pain they can imagine (ie, childbirth, major surgery, or kidney stone) and that ''1'' represents no sensation at all.
Time frame: baseline, 6, 12 and 24 months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.