The purpose of this study is to devise repositioning method of a left-sided double lumen tube into left mainstem bronchus in case of misplacement into right mainstem bronchus.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
50
When a left-sided double lumen tube were placed in right mainstem bronchus, after withdrawing the tube into mid-trachea, it was re-advanced with patient's head turned right and counterclockwise rotation of the tube.
Seoul National University Hospital
Seoul, Seoul, South Korea
repositioning success rate
Time frame: up to 10 minutes
anatomic parameters
tracheal diameter, position of carina, angle between trachea and left mainstem bronchus
Time frame: up to 1 hours