Stapled hemorrhoidopexy has gained wide acceptability among colorectal surgeons because of less postoperative pain compared with excisional surgery, however a still relevant percentage of postoperative bleedings and long-term hemorrhoid recurrence are reported. A new stapler device has been designed to overcome these drawbacks by modifying the stapled sutures and by increasing the space for mucosal resection in the case of the stapler. This randomized controlled study was aimed to demonstrate whether the new EEA stapler Covidien was able to resect more quantity of prolapsed mucosa than the traditional PPH 01/03 Ethicol Endosurgery by measuring the surface of the resected specimen and to demonstrate if the modified stapled sutures can ensure better intraoperative hemostasis by measuring the number of overstitches required to get perfect hemostasis during the operation.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
120
stapled hemorrhoidopexy will be performed using the EEA stapler Covidien
stapled hemorrhoidopexy will be performed using the PPH01/03 Ethicon EndoSurgery
Dept of Emergency and Organ transplantation
Bari, Italy
quantity of anorectal mucosa resected using two different circular staplers
The surface (in cm2)of anorectal mucosa resected during stapled hemorrhoidopexy for III degree hemorrhoids, using two different circular staplers will be compared
Time frame: 1 hour following the end of the operation
Number of hemostatic stitches required to get perfect hemostasis using 2 different staplers
the number of hemostatic sutures required to get perfect hemostasis during stapled hemorrhoidopexy using 2 different staplers for III degree hemorrhoids
Time frame: 1 hour after each operation