The purpose of this study is to determine the correlation between actual epidural needle depth (ND) and the use of ultrasound with an epidural depth equation (EQ-US) to estimate epidural depth (Est-D) in morbidly obese parturients. It is well documented that in women with a BMI greater than 40 kg/m2 successful epidural placement is more difficult. To the best of our knowledge the use of an epidural depth equation, which was developed in an earlier study using height and weight, with ultrasound visualization will improve identification of the epidural space.
The investigators plan to enroll women who are morbidly obese (BMI \> 40 kg/m2) and request epidural analgesia for labor. After written informed consent, 160 patients will have the use of the epidural depth equation with ultrasound (EQ-US) to estimate epidural depth (Est-D). US visualization of the epidural space will be completed by the principle investigator who has had extensive training in epidural US visualization. The EQ-US depth will be recorded. After US use, another provider who is listed as an investigator will place the epidural catheter without prior knowledge of the estimated epidural depth with the use of the equation and US. The actual needle depth to the epidural space (ND) will be recorded. Data collected from the patient's medical record will include demographic data (age, height, weight) gravidity, parity, and cervical dilation. Measured variables will include the estimated epidural depth (Est-D) as measured by the epidural depth equation with the use of ultrasound (EQ-US), and actual epidural needle depth (ND). The investigators believe that the use of ultrasound with the epidural depth equation (EQ-US) to estimate epidural depth (Est-D) in morbidly obese parturients will have a high correlation with actual epidural needle depth (ND).
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DIAGNOSTIC
Masking
NONE
Enrollment
160
Ultrasound to measure depth to the epidural space in morbidly obese parturients
Magee-Womens Hospital
Pittsburgh, Pennsylvania, United States
Correlation Between Actual Epidural Needle Depth (ND) and Estimated Epidural Depth (Est-D)
Measured using the Pearson correlation coefficient between actual epidural needle depth (ND) and epidural depth as estimated by the epidural depth equation (EQ-US) followed by ultrasound (longitudinal and transverse planes) measurement.
Time frame: at the time of labor epidural catheter insertion (an average of 5 minutes for ultrasound visualization)
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.