The objective of the study is to examine the safety of two different hemoglobin (Hgb)-based transfusion triggers in patients post cardiac surgery.
Nearly 20% of blood transfusions in the United States are given to in patients undergoing cardiac surgery. Despite the many blood conservation techniques that are available, safe, and efficacious for patients, many of these operations continue to be associated with significant amounts of blood usage. We believe that transfusion protocols which employ specific guidelines for transfusion can decrease blood product usage and improve outcomes for patients undergoing cardiac surgery. Our goal is to demonstrate that a carefully chosen trigger can achieve better outcomes. Our hypothesis is that a transfusion trigger of Hgb 7.5 g/dl will lead to decreased utilization of blood transfusions and will have many positive effects on the patients post cardiac surgery in addition to substantial cost savings. We will use an evidence based approach to observe the relative safety of a conservative transfusion trigger (7.5 g/dl) as compared to a more liberal trigger (9.0 g/dl). We will also study the effect of blood conservation on the incidence of transfusion-related complications such as transfusion related lung injury (TRALI) and infectious complications as well as length of hospital stay, cost and ventilator time.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
PREVENTION
Masking
NONE
Conservative transfusion arm: Subjects randomized to the conservative transfusion arm will receive transfusions of PRBCs post-surgery only when their Hgb level measures \< 7.5 g/dl. Blood products should be given to maintain Hgb levels \>7.5 g/dl.
Liberal transfusion arm: Subjects randomized to the liberal transfusion arm will receive transfusions of PRBCs post-surgery only when their Hgb level measures \< 9.0 g/dl. Blood products should be given to maintain Hgb levels \> 9.0 g/dl.
Hackensack University Medical Center
Hackensack, New Jersey, United States
Safety of the lower hemoglobin transfusion trigger of 7.5 g/dl against the higher hemoglobin transfusion trigger of 9.0 g/dl.
This outcome measure is a simultaneous assessment of the multiple end points duration of pressor use, symptomatic anemia, anemia-associated hypotension within 48 hours post surgery and Hgb recovery by day 4 post-surgery.
Time frame: The assessment will last untill day 4 post surgery
Rate of incidence of transfusion related complications between the two randomizations arms.
The comparison will be based on a composite end point consisting of transfusion related lung injury (TRALI) that is ARDS, ventilator time\>24 hours, pneumonia; stroke (permanent/transient); MI and renal failure.
Time frame: This will be compared during the hospital stay, untill 30 days after discharge.