The Multiway stimulator is a novel TMS stimulator with several new and unique properties. Currently standard TMS devices include a single channel, and can operate only a single coil. The Multiway stimulator includes five channels which can operate up to five independent TMS coils, either simultaneously or sequentially. The Multiway device may be used to obtain a differential activation of various brain regions. For instance it can be used to induce high frequency stimulation of a certain brain region, thus inducing facilitation, while simultaneously stimulate at low frequency in another brain region, leading to inhibition. The purpose of the study is to explore the efficacy and safety of Multiway deep TMS in comparison to a single channel DTMS treatment in subjects with MDD. Subjects will be treated with one of two designs of the study device (the Multiway Coil TMS Device): 1. Single Channel with a coil placed over the left PFC (10 Hz). 2. Four channels: a. 10 Hz over the left PFC. b. 1 Hz over the right PFC. c. 10 Hz over the left parietal cortex. d. 1 Hz over the right parietal cortex.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
60
During the single channel treatment trial period the patients will receive the following dose of rTMS: 10 Hz - left DLPFC ( 10 Hz, at 120% MT, 3 sec pulse train, 20 second inter-train interval, 55 trains, i.e. a total of 1650 pulses per session, a total of 20 sessions in the study and a cumulative exposure (total number of pulses) of 33,000pulses in 4 weeks)
During the four channels treatment trial period the patients will receive the following dose of rTMS: 10 Hz- left DLPFC, 1Hz - right DLPFC together, and than 10 Hz- left parietal cortex, 1Hz - right parietal cortex together. 10 Hz protocol: ( 10 Hz, at 120% MT, 3 sec pulse train, 20 second inter-train interval, 55 trains, i.e. a total of 1650 pulses per session, a total of 20 sessions in the study and a cumulative exposure (total number of pulses) of 33,000pulses in 4 weeks) 1 Hz protocol: 1 Hz, at 120% MT, 5 min pulse train, 1 min inter-train interval, 6 trains, i.e. a total of 1800 pulses per session, a total of 20 sessions in the study and a cumulative exposure (total number of pulses) of 36,000 pulses in 4 weeks)
Shalvata Mental Health Center
Hod HaSharon, Israel
shalvata MHC
Hod HaSharon, Israel
Clinical antidepressant response
Clinical antidepressant response at the end of the treatment, defined as a decline in Hamilton depression rating scale (HDRS-21) from the baseline rating by 50%.
Time frame: day 20
Clinical antidepressant remission
Clinical antidepressant remission at the end of the treatment, define as exit HDRS-21 \<10.
Time frame: day 20
Symptomatic improvement
Symptomatic improvement at the 4-week end point as measured with Hamilton Anxiety Rating Scale ( HARS), Quick Inventory of Depressive Symptomatology - Self Report (QIDS-SR) , Clinical Global Impression (CGI), Cognitive improvement measured by a computerized battery of tests (CANTAB).
Time frame: day 20
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.