The objective of this study is to assess the safety and effectiveness of the automatic atrioventricular (AV) delay and interventricular (VV) delay optimization algorithm used in the PARADYM RF SONR Cardiac Resynchronization Therapy with Defibrillation (CRT-D) device (Model 9770) in combination with the SonRtip Lead, which includes a SonR sensor in the tip of the atrial pacing lead, and compatible SmartView programming software. This study will evaluate the effectiveness of the automatic optimization algorithm in increasing the rate of patients responding to the therapy as compared to an echocardiographic optimization method. This study will also evaluate the safety and effectiveness of the SonRtip atrial pacing lead.
Since the introduction of cardiac resynchronization therapy (CRT) on a large scale, it has been observed that approximately 30% of recipient patients are non-responsive to therapy. This non-responsiveness can be decreased by optimizing the device programming, particularly the stimulation rate, paced and sensed atrioventricular (AV) delay, and the interventricular (VV) delay. All CRT patients need a 100% rate of ventricular capture, but beyond this the achievement of therapy effectiveness requires the identification of the optimal pacing configuration, which varies among patients. The optimization of CRT systems, usually based on ultrasound imaging is time-consuming and the number of patients in need of multiple optimization procedures due to ventricular remodeling is growing rapidly. The mechanical effects of a more coordinated contraction result in a shortening of the isovolumetric contraction phase and the pre-ejection time, and an increase in LV dP/dt (change in left ventricular pressure over time. The concept of measuring contractility with an implantable accelerometer was first clinically validated through a multicenter study on a rate responsive pacing system (BEST - Living from SORIN Biomedica) in 1996. This study positively demonstrates that measurement of Peak Endocardial Acceleration signal (called PEA or SonR) is feasible and reliable in the long-term, both for the purpose of rate response and as a hemodynamic monitor of cardiac function. More recent clinical studies have demonstrated that optimal VV and AV Delays determined using algorithms based on SonR signal analysis (SonR method) are correlated with the highest hemodynamic improvement and lead to significant clinical benefit for the patients, thus reducing the rate of non-responsiveness to CRT therapy. Therefore, automatic AV and VV delay optimization in patients with CRT devices could benefit both the patient and physician.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
DOUBLE
Enrollment
1,039
SonR CRT Optimization
Echocardiography Optimization
Brookwood Medical Center CardioVascular Associates
Birmingham, Alabama, United States
AZ Heart Rhythm Center
Phoenix, Arizona, United States
Brotman Medical Center
Culver City, California, United States
Hoag Hospital
Newport Beach, California, United States
Scripps Mercy Hospital
San Diego, California, United States
Evaluation of SonR CRT Optimization Effectiveness in terms of proportion of responders at 12 months. The investigational(SonR)and control groups(ECHO)will be compared in a non-inferiority context employing a clinically meaningful difference of 10%.
The analysis will be done on all patients implanted with the entire system who have been followed out to 12 months. The patients will be classified as improved, unchanged or worsened based on composite criteria(death/heart failure (HF) events,New York Heart association(NYHA) class), Quality of life (QOL). In the event that the non-inferiority test is met, a test of superiority will be conducted comparing the treatment and control groups.
Time frame: 12 months
Evaluation of Lead Safety: Acute SonRTipLead Complication-Free Rate (at 3 months)
SonRtip acute lead-related complication-free rate is defined as the proportion of patients not experiencing any complication related to the SonRtip lead within 3 months post-implant, relative to the total number of patients implanted with the lead.All patients who are successfully implanted with SonRtip lead will be included.
Time frame: 3 months
Evaluation of Lead Safety: Chronic SonRTipLead Complication-Free Rate (from 3 months to 12 months)
SonRtip lead-related complication-free rate is defined as the proportion of patients not experiencing any complication related to the SonRtip lead from 3 to 12 months post-implant.All patients who are successfully implanted with SonRtip lead will be included.
Time frame: 12 months
Evaluation of CRT effectiveness and CRT Safety: evaluation of Mortality and HF hospitalizations at 12 months
This endpoint will compare treatment arms in a non-inferiority hypothesis test of the proportion of subjects that either died from any cause, or were hospitalized for heart failure
Time frame: 12 months
Evaluation of CRT effectiveness and CRT therapy: Proportion of patients worsened at 12 months
This endpoint will compare treatment arms in a non-inferiority hypothesis test of the proportion of subjects classified as worsened, in order to evaluate the potential detrimental effects of the optimization method
Time frame: 12 months
SonR tip lead pacing threshold
For all patients implanted with the SonRtip lead.
Time frame: 24 months
SonR tip lead sensing threshold
For all patients implanted with the SonRtip lead.
Time frame: 24 months
SonR tip lead pacing impedance
For all patients implanted with the SonRtip lead.
Time frame: 24 months
Evaluation of CRT effectiveness and CRT and System Safety: Report deaths for any cause
The report of the deaths occurred consists of the percentage of dead patients, the causes of death, the time to death, the survival curves.
Time frame: 24 months
Report Heart Failure-related events to assess CRT effectiveness
For all patients implanted it will be reported the percentage of patients with events, number of events for patients, event type, time to first occurence, survival curves)
Time frame: 24 months
Report Quality of life (QOL) improvement to assess CRT effectiveness (percentage of patients with improvements in QOL)
In all patients implanted the evaluation of the Quality of Life Score will consist of reporting the percentage of patients who showed improvement in their KCCQ Score at each follow-up post-implant
Time frame: 24 months
Report NYHA class improvement to assess CRT effectiveness (the percentage of patients with improved in NYHA class)
In all patients implanted the evaluation of the NYHA Classification will consist of reporting the percentage of patients who improved at least one NYHA class at each follow-up post-implant
Time frame: 24 months
Evaluation of CRT effectiveness: Report echocardiographic parameters trend at M12
The intra-patient variations of the echocardiographic parameters measured at M12 as compared to those measured at baseline. The echo measures will be validated by an independent and blinded core lab
Time frame: 12 months
Evaluation of SonR CRT Optimization Effectiveness - Superiority by assessment the proportion of responder patients in SonR group
The analysis will be done on all patients implanted with the entire system. The patients will be classified as improved, unchanged or worsened based on composite criteria(death/heart failure events,NYHA class, Quality of life (QOL).
Time frame: 18/24 months
Evaluation of the time spent for CRT optimization by the physician on optimization in each group (sonR and ECHO)
The amount of time (mean, median, standard deviation, minimum, maximum)in each group will be evaluated in all patients implanted
Time frame: 24 months
Evaluation of the Number of re-optimizations performed in both groups (SonR and ECHO)
In all patients implanted will be evaluated the number of re-optimizations performed (mean, median, standard deviation, minimum, maximum) in each group (study and control).
Time frame: 24 months
Report Adverse Events for both group to assess CRT effectiveness / System Safety
For all patients enrolled all Adverse Events will be reported.
Time frame: 24 months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Broward General Medical Center
Fort Lauderdale, Florida, United States
St. Vincent's HealthCare
Jacksonville, Florida, United States
Piedmont Hospital Research Institute
Atlanta, Georgia, United States
Rush University Medical Center
Chicago, Illinois, United States
Swedish Covenant Hospital
Chicago, Illinois, United States
...and 115 more locations