Temperature in the vitreous cavity decreases during vitrectomy, and the same effect is seen during an uneventful phaco surgery. Significant changes occur between the baseline temperature and after every step of the surgery.
A 23-gauge thermometer probe inserted prior to the beginning of the cataract surgery to measure the vitreous temperature at different stages of the procedure (capsulorrhexis, hydrodissection, phacomulsification, irrigation/aspiration and intraocular lens (IOL) implantation). Room temperature also registered during every step. At the end of the surgery, oral temperature will be measured.
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
BASIC_SCIENCE
Masking
NONE
Transurgical measurement of temperature
Asociación Para Evitar la Ceguera en México
Mexico City, Mexico City, Mexico
Vitreous temperature
Temperature of the vitreous is taken every five minutes from the start of a phacoemulsification. Also Temperature is take after every step of the surgery (capsulorhexis, hydrodissection, phacoemulsification, irrigation/aspiration, IOL implantation).
Time frame: Every five minutes during a phacoemulsification procedure, and at every step of the surgery