Right ventricular (RV) failure occurs in an estimated 5-41% of cases involving left ventricular assist device (LVAD) implantation and has been shown to adversely affect peri-operative morbidity and mortality. Current therapies to improve RV dysfunction pre and post-operatively are limited. Inhaled milrinone has been shown in several small human studies to be safely tolerated and provide favorable effects on pulmonary hemodynamics. Study Hypothesis: Delivery of inhaled milrinone, a phosphodiesterase III inhibitor, may provide pulmonary artery vasodilation and therefore improved RV function in patients with end stage heart failure receiving HeartMate II LVAD as a bridge to cardiac transplantation or as destination therapy. Specifically, we aim to: * demonstrate safety of inhaled milrinone in this patient cohort * demonstrate efficacy of inhaled milrinone in this patient cohort
Right ventricular (RV) failure occurs in an estimated 5-41% of cases involving left ventricular assist device (LVAD) implantation and has been shown to adversely affect peri-operative morbidity and mortality. Current therapies to improve RV dysfunction pre and post-operatively are limited. Inhaled milrinone has been shown in several small human studies to be safely tolerated and provide favorable effects on pulmonary hemodynamics. Study Hypothesis: Delivery of inhaled milrinone, a phosphodiesterase III inhibitor, may provide pulmonary artery vasodilation and therefore improved RV function in patients with end stage heart failure receiving HeartMate II LVAD as a bridge to cardiac transplantation or as destination therapy. Specifically, the aims are: demonstrate safety of inhaled milrinone in this patient cohort demonstrate efficacy of inhaled milrinone in this patient cohort
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
TREATMENT
Masking
NONE
Enrollment
10
1 mg/ml milrinone (dissolved in dextrose) and diluted in 0.9% normal saline in a 1:1 ratio to final drug concentration of 0.5mg/ml will be delivered via an IV pump at a fixed dose of 12 ml/hour which will run into a vibrating mesh nebulizer reservoir, connected to the mechanical ventilator circuit. Inhaled milrinone will begin at time of resumption of mechanical ventilation when initiating wean from cardiopulmonary bypass after LVAD implantation in the operating room, and run continuously for a total maximum duration of 24 hours OR until the patient is extubated whichever occurs first. Plasma milrinone levels will be assessed to determine if systemic milrinone absorption occurs after prolonged milrinone inhalation.
0.5 mg/ml inhaled nebulized milrinone deliver at 12 ml/hr continuously until either 24 hours or extubated.
University of Nebraska Medical Center
Omaha, Nebraska, United States
Safety: Incidence of Arrhythmias, Hypotension and Hypersensitivity Reaction
1. Arrhythmias: * Atrial * Ventricular 2. 'Sustained' hypotension 3. Hypersensitivity reaction to milrinone
Time frame: 12 and 24 hours
Efficacy - Hemodynamic
Invasive Hemodynamic pulmonary catheter: * PAS, PAD, mPAP, RA pressures, PCWP, CI, RVSWi (calculated), TPG, PVR, and SvO2
Time frame: 30, 60 minutes, then every 4 hours thereafter
Efficacy - Echocardiographic
Echocardiographic * RV dimensions * RV systolic functional assessment * Tricuspid valve regurgitation * Pulmonary Vascular resistance
Time frame: Pre-op Echocardiography, intraoperative TEE (before and after inhaled milrinone) and postoperative Echocardiography within 48 hours of milrinone initiation