The purpose of this study is to investigate the benefit of Closed-loop System for Oxygen Delivery (FreeO2) as compared with fixed oxygen flow during endurance shuttle walking test in patients with Chronic obstructive pulmonary disease (COPD), oxygen therapy and hypercapnia. The study was designed to test the following hypotheses: As compared with fixed oxygen flow, the FreeO2 Oxygen Delivery system leads to higher exercise tolerance (distance during ESWT) and lower desaturation events without increase in hypercapnia in patients with COPD, oxygen therapy and hypercapnia. As compared with fixed oxygen flow, the FreeO2 Oxygen Delivery system leads to lower dyspnea and leg fatigue scores at a given endurance time during the shuttle walking test in patients with COPD, oxygen therapy and hypercapnia. As compared with fixed oxygen flow, the FreeO2 Oxygen Delivery system leads to lower cardiac and respiratory frequencies at a given endurance time during the shuttle walking test in patients with COPD, oxygen therapy and hypercapnia.
Background: In spite of oxygen therapy, desaturations frequently occur during exercise in COPD patients. Although current recommendations are to add 1 L/min to the baseline oxygen flow during exertion, a new closed-loop system (FreeO2) automatically and continuously adjusts the oxygen flow to the patient's needs based on the oxygen saturation by pulse oximetry (SpO2), end-tidal CO2 (EtCO2) and respiratory rate. A preliminary study showed significant improvement in exercise tolerance in COPD patients not needing oxygen therapy. Although oxygen flow could be two fold increased during exercise, a worsening hypercapnia is plausible in severe COPD. Aim of this study is to evaluate this system during endurance shuttle walking test in COPD patients with oxygen therapy and hypercapnia. Methods: The investigators proposed to conduct a controlled, randomized cross-over study comparing the efficacy of a Closed-loop System for Oxygen Delivery (FreeO2) as compared with fixed oxygen flow during an endurance shuttle walking test in patients with COPD, oxygen therapy and hypercapnia.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
DOUBLE
Enrollment
15
FreeO2 automatically adjusts the oxygen flow delivered to patients based on the SpO2 signal and collects the cardiorespiratory parameters
FreeO2 system does not adjust oxygen flow but collects the cardiorespiratory parameters
Hopital Universitaire
Grenoble, France
Centre ATRIR
Nyons, France
Centre Henri BAZIRE
Saint-Julien-de-Raz, France
Change in Endurance time
Duration during the endurance shuttle walking test
Time frame: Day 0 (inclusion) + 14 and D0 +21
Change in Dyspnea during ESWT
Visual analogic scores of dyspnea during the endurance shuttle walking test
Time frame: Day 0 (inclusion) + 14 and D0 +21
Change in Muscle fatigue during ESWT
Visual analogic scores of leg discomfort during the endurance shuttle walking test
Time frame: Day 0 (inclusion) + 14 and D0 +21
Change in Respiratory frequency during ESWT
Respiratory frequency measurement by the FreeO2 system during the endurance shuttle walking test
Time frame: Day 0 (inclusion) + 14 and D0 +21
Change in PaCO2 during ESWT
EtCO2 measurement by the FreeO2 system during the endurance shuttle walking test
Time frame: Day 0 (inclusion) + 14 and D0 +21
Hypercapnia level at baseline
Blood gases at rest
Time frame: Day 0 (inclusion) - baseline evaluation
Change in Cardiac frequency during ESWT
Cardiac frequency measurement by the FreeO2 system during the endurance shuttle walking test
Time frame: Day 0 (inclusion) + 14 and D0 +21
Change in SpO2 during ESWT
Pulse oxygen saturation during the endurance shuttle walking test
Time frame: Day 0 (inclusion) + 14 and D0 +21