The purpose of this study is to evaluate the immediately clinic and ultramicroscopic myocardial cellular ischemia and reperfusion to replace of the mitral valve using arrested heart versus on-pump empty beating heart surgical techniques.
During open-heart surgery prevention of ischemia and reperfusion following cardioplegic arrest are essential for myocardial protection. Beating heart surgery on normothermic bypass simulates physiologic cardiac status and is good method for myocardial protection. A comparison of both available techniques for valve replacement arrested heart versus on-pump empty beating heart of the clinical and ultramicroscopic myocardial alterations will allowed to better understand myocardial protection because eliminated the use of cardioplegia and the corollary risk of ischemic reperfusion injury.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
NONE
Enrollment
34
Mitral valve replacement (MVR) was performed using a metallic or bioprostheses substitution by interrupted suture. For the beating heart the prostheses was functionally tested before removal of the retrograde perfusion catheter and for the arrested heart the prosthesis was artificially tested by pumping saline into the left ventricle. The tricuspid valve repair was done following De Vegas' technique in both groups
Mitral valve replacement (MVR) was performed using a metallic or bioprostheses substitution by interrupted suture. For the beating heart the prostheses was functionally tested before removal of the retrograde perfusion catheter and for the arrested heart the prosthesis was artificially tested by pumping saline into the left ventricle. The tricuspid valve repair was done following De Vegas' technique in both groups
Hospital Ana Neri
Salvador, Estado de Bahia, Brazil
mitral valve replacement
Mitral valve replacement (MVR) was performed using a metallic or bioprostheses substitution by interrupted suture. For the beating heart the prostheses was functionally tested before removal of the retrograde perfusion catheter and for the arrested heart the prosthesis was artificially tested by pumping saline into the left ventricle. The tricuspid valve repair was done following De Vegas' technique in both groups with the beating heart also in the group B.
Time frame: 1hour , 3 hours and 1 hour after surgery procedure
Ultramicroscopic evidences of ischemia
During the surgery myocardial biopsies were performed as full thickness transmural specimen of three small fragments for electromicrospic analysis
Time frame: 1hour, 3 hours and 1 hour after aortic clamping
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.