Few studies look into cerebral blood flow (CBF) changes during emergence from general anesthesia for craniotomy. The purpose of this study is to demonstrate CBF changes during emergence from general anesthesia for craniotomy, through monitoring blood oxygen saturation of jugular vein bulb and transcranial Doppler.
30 patients undergoing selective craniotomy (craniotomy group) for supratentorial brain tumor removal and 30 patients undergoing selective abdominal surgery (abdominal surgery group) are planned to be enrolled in the study. Mean blood flow velocity in middle cerebral artery (Vmca), mean arterial pressure (MAP), blood oxygen saturation of jugular vein bulb (SjvO2) (only measured in craniotomy group)and arterial CO2 partial pressure (PaCO2) will be measured before general anesthesia, at tracheal extubation, and 30,60, 90, 120 min after extubation in both groups.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
PREVENTION
Masking
NONE
Enrollment
60
A 2-MHz Transcranial Doppler probe (MULTI-DOP P2.2C; DWL, Elektronische Systeme GmbH, Germany) will be used to measure both sides of Vmca of both patients undergoing craniotomy and patients undergoing abdominal surgery. The signal will be range-gated to a depth of 45 to 60 mm at temporal bone window to achieve the optimal signal according to standard techniques. The measures will be recorded in the operation room before anesthesia, in the recovery room at extubation, 30, 60, 90, and 120 min after extubation.
After local anesthesia, a jugular venous bulb catheter(16G, manufactured by Arrow International Inc. USA) will be placed in the dominant side. The proper placement of the tip of the catheter in the jugular bulb will be confirmed later by a postoperative lateral skull X-ray. SjvO2 (blood sample will be drawn slowly at a speed of 2ml per minute) will be measured before anesthesia, at extubation, 30, 60, 90, and 120 min after extubation.
Huashan Hospital
Shanghai, Shanghai Municipality, China
Mean Blood Flow Velocity in Middle Cerebral Artery
It was the baseline mean blood flow velocity in middle cerebral artery.
Time frame: before general anesthesia
Mean Blood Flow Velocity in Middle Cerebral Artery
Time frame: after surgery at extubation (average surgery duration: craniotomy group 214min, abdominal group 207min)
Mean Blood Flow Velocity in Middle Cerebral Artery
Time frame: 30min after extubation
Mean Blood Flow Velocity in Middle Cerebral Artery
Time frame: 60min after extubation
Mean Blood Flow Velocity in Middle Cerebral Artery
Time frame: 90min after extubation
Mean Blood Flow Velocity in Middle Cerebral Artery
Time frame: 120min after extubation
Oxygen Saturation of Jugular Venous Bulb
Time frame: before general anesthesia
Oxygen Saturation of Jugular Venous Bulb
Time frame: at extubation
Oxygen Saturation of Jugular Venous Bulb
Time frame: 30min after extubation
Oxygen Saturation of Jugular Venous Bulb
Time frame: 60min after extubation
Oxygen Saturation of Jugular Venous Bulb
Time frame: 90min after extubation
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Surgery types include total or subtotal removal of tumors.For all surgical procedures, general anesthesia will be maintained with isoflurane (0.5-1.0 minimal alveolar concentration (MAC) expired), repeated boluses of fentanyl (1\~2 µg/kg IV), and continuous vecuronium 50~70 IV. All patients will be mechanical ventilated with oxygen. During anesthesia, blood pressure and heart rate will be kept stable, within ±10% of the preoperative levels. Hematocrit (Hct) will be maintained higher than 30%. After surgery, tracheal extubation will be performed when patients regain full muscle strength, breathe spontaneously with acceptable oxygenation and normocapnia.
After local anesthesia, an intra-arterial pressure line(I.V. catheter and pressure line kit are both manufactured by Smiths Medical International Ltd. USA) will be inserted in radial artery. Sample blood will be drawn from the line before anesthesia, at tracheal extubation, and 30, 60, 90, 120 min after tracheal extubation.
For all surgical procedures, general anesthesia will be maintained with isoflurane (0.5-1.0 minimal alveolar concentration (MAC) expired), repeated boluses of fentanyl (1\~2 µg/kg IV), and continuous vecuronium 50~70 IV. All patients will be mechanical ventilated with oxygen. During anesthesia, blood pressure and heart rate will be kept stable, within ±10% of the preoperative levels. Hematocrit (Hct) will be maintained higher than 30%. After surgery, tracheal extubation will be performed when patients regain full muscle strength, breathe spontaneously with acceptable oxygenation and normocapnia.
Oxygen Saturation of Jugular Venous Bulb
Time frame: 120min after extubation