This study is a long-term, prospective, and controlled evaluation of the mechanical dyssynchrony induced by right ventricular apical pacing, both in acute (spontaneous and stimulated) and chronic (12 and 24 months); the study also evaluates the benefit of an alternative pacing site through measures of dyssynchrony in acute and chronic.
Permanent cardiac pacing plays an important role in cardiac disease management. Since early studies on right ventricular pacing, apex has been the preferred implant site for transvenous endocardial ventricular leads for several reasons: ease of placement, lead stability as well as the design characteristics of the electrode and the fixation system. It is now also accepted, however, that right ventricle pacing causes a long term deterioration of left ventricular function through complex effects, both at the structural level of the heart wall and at the hemodynamic level in left ventricular load conditions. It is possible that this deterioration is due to a dyssynchrony of contraction induced by pacing at the right ventricular apex. Some authors suggest to pace the right ventricle at alternative sites, i.e. the medium septum (RVS) region, to guarantee a more physiological activation pattern, especially in patients expected to receive high pacing percentages. However, unequivocal evidences that stimulation of the right ventricular septum is more physiological than the apical pacing are still missing. Nonetheless, it should be noted that, although a number of studies refer to RV septum as the alternative site for pacing , poor attention has been paid to the unambiguous definition of RV septum region itself. A clear definition and a proper evaluation of the alternative site is therefore important. Furthermore, from a procedural point of view, it has been demonstrated that acute and chronic electrical performances of the leads positioned at alternative sites, in particular in the region of mid septum, are equivalent to those of the leads positioned at the apical site. The purpose of this study is to perform a comprehensive assessment of the electrical and mechanical measures obtained by pacing standard RV site (Right ventricular apex, RVA) and alternative RV site (right ventricular septum, RVS). Specifically, the two pacing sites will be compared in terms of electrical dyssynchrony, as assessed by ECG criteria, and in terms of mechanical dyssynchrony, as assessed by echocardiographic criteria. The primary end point of the study is defined through the evaluation of dyssynchrony measured both in spontaneous rhythm (Vs) and paced rhythm (Vp). The delay between the time to peak systolic velocity of the septum and the LV free wall will be used to define the degree of dyssynchrony; this measurement will be obtained by TDI echocardiographic technique. Patients will receive any commercially available dual-chamber implantable pacemakers, according to current standard indications. At the end of the implantation and at follow-up visits (12 and 24 months) device programming will follow the clinical practice of the center.
Study Type
INTERVENTIONAL
Allocation
NON_RANDOMIZED
Purpose
PREVENTION
Masking
DOUBLE
Enrollment
408
Azienda Ospedaliero Universitaria "Vittorio Emanuele"
Catania, Italy
RECRUITINGOspedale Santa Maria di Loreto Mare
Naples, Italy
RECRUITINGLV dyssynchrony as measured by Electromechanical delay (EMD
The primary outcome measure of this study is to compare the effect of RV Septal (RVS) versus RV Apical (RVA) pacing as measured by echocardiographic/Doppler Index
Time frame: 2 weeks
Number of heart failure-related hospitalization
To compare the rate of heart failure-related hospitalization between RVS versus RVA pacing
Time frame: 24 months
Right ventricular lead and total implant procedure time, fluoroscopy time
To compare the procedural time of RVS versus RVA pacing
Time frame: Implant
Change from baseline in R wave in 12-lead ECG
To investigate the relationship between the ECG characteristics at baseline and response to cardiac pacing (as measured by echocardiography as defined in primary outcome measure) at implant and 24 months
Time frame: 24 months
Absolute change in LVEF
To evaluate the Left ventricular diastolic and systolic function as measured by Echocardiographic response of absolute change in LVEF
Time frame: 24 months
LV dyssynchrony as measured by Electromechanical delay (EMD)
The secondary outcome measure of this study is to compare the effect of RVS versus RVA pacing as measured by echocardiographic/Doppler Index. This extends to 24 months the results obtained with the primary objective at 2 weeks
Time frame: 24 months
Symptoms and quality of life scores
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
To investigate the relationship between the right ventricular lead position and response to cardiac pacing in terms of symptoms and quality of life scores as measured by short form (SF)-12 scores
Time frame: 24 months