Recently, it was reported that when vancomycin levels are determined after port sampling, levels can be falsely increased potentially leading to wrong dose adjustments. The investigators conducted an in vitro experiment using several central venous port devices, in which different flushing techniques were evaluated yielding residual vancomycin levels of less than 0.5 mg/L. In this study, the investigators want to evaluate this flushing technique in vivo in 15 patients admitted with catheter-related infection and treated with systemic vancomycin and vancomycin antibiotic lock. The purpose is to assess if correct flushing can avoid spurious vancomycin levels obtained via port sampling.
Study Type
OBSERVATIONAL
Enrollment
15
comparison of central (via port device) and peripherally obtained vancomycin levels: the difference, when using the new flushing technique, is allowed to be maximally 0.5 mg/L
Time frame: central and peripheral vancomycin levels will be obtained during steady state: this means starting from the 4th dose (= day 2) of vancomycin treatment. Vancomycin is usually given during 14 days after the last positive blood culture.