A randomised, comparative, prospective, single-blinded trial of two hip prosthesis: 1. Marathon cemented all-poly acetabular cup(Depuy, Warsaw, Indiana), Corail uncemented femoral stem(Depuy, Warsaw, Indiana), 32mm Alumina Biolox Forte femoral head(Depuy, Warsaw, Indiana) and 2. Pinnacle/Marathon uncemented cup(Depuy, Warsaw, Indiana), Corail uncemented femoral stem(Depuy, Warsaw, Indiana), 32mm Alumina Biolox Forte femoral head(Depuy, Warsaw, Indiana) There will be a further in-group randomisation to a Corail femoral stem with or without a collar, creating a number of 4 study-groups in total. The aims of the study are: * To compare polyethylene wear and migration of the moderately cross-linked Marathon polyethylene in a cemented version(Marathon) and in an uncemented cup(Pinnacle/Marathon) * To evaluate micromigration and periacetabular bone mineral density of the 2 cups using radiostereometry(RSA) * To evaluate the migration patterns and proximal femoral bone density changes around the Corail stems with and without a collar
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Purpose
TREATMENT
Masking
SINGLE
Enrollment
61
Uncemented THA using Pinnacle-100/Marathon XLPE(Depuy, Warsaw, IN) acetabular component and Corail(Depuy,Warsaw,IN)collared femoral stem with 32mm Alumina Biolox Forte(Depuy,Warsaw,IN). Tantalum beads will be inserted into periprosthetic bone.
Reversed hybrid THA using cemented Marathon XLPE(Depuy,Warsaw,IN) acetabular component and an uncemented Corail(Depuy,Warsaw,IN)collared femoral component with 32 mm Alumina Biolox Forte(Depuy,Warsaw,IN)head. Tantalum beads will be inserted into periprosthetic bone.
Uncemented THA using Pinnacle-100/Marathon XLPE(Depuy, Warsaw, IN) acetabular component and Corail(Depuy,Warsaw,IN)collarless femoral stem with 32mm Alumina Biolox Forte(Depuy,Warsaw,IN). Tantalum beads will be inserted into periprosthetic bone.
Reversed hybrid total hip arthroplasty using cemented Marathon XLPE(Depuy,Warsaw,IN) acetabular component and an uncemented Corail(Depuy,Warsaw,IN)collarless femoral component with 32 mm Alumina Biolox Forte(Depuy,Warsaw,IN)head. Tantalum beads will be inserted into periprosthetic bone.
Department of Orthopaedic Surgery, Haukeland University Hospital
Bergen, Norway
Polyethylene wear
Comparison of polyethylene wear rates in a modular uncemented acetabular component and a cemented all-polyethylene acetabular component using radiostereometric analysis
Time frame: After 5 years of follow-up
Component migration-cup
Comparison of the migration of a modular uncemented acetabular component and a cemented all-polyethylene acetabular component using radiostereometric analysis.
Time frame: After 5 years of follow-up
Periprosthetic bone mineral density
Differences in bone mineral density around a cemented and an uncemented acetabular component using Dual X-ray absorptiometry. Differences in bone mineral density around an uncemented fully HA-coated femoral component with or without a collar using Dual X-ray absorptiometry.
Time frame: After 2 years of follow-up
Component migration-stem
Comparison of the migration of an uncemented fully HA-coated femoral component with and without a collar using radiostereometric analysis.
Time frame: After 5 years of follow-up
Clinical outcome
Comparison of clinical results between study groups using HHS and PROMs
Time frame: After 5 years of follow-up
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.