Bioequivalence study to confirm that a NTS with a polyisobutylene (PIB) adhesive from an alternative supplier delivers the same nicotine blood profile as that of the currently approved NTS with a polyisobutylene adhesive from the current supplier.
Study Type
INTERVENTIONAL
Allocation
RANDOMIZED
Masking
SINGLE
Enrollment
40
nicotine transdermal patch
Celerion NEBRASKA
Lincoln, Nebraska, United States
Area Under the Curve From Time 0 to the Last Quantifiable Sample, AUC(0-t)
Following randomization, the nicotine patches; reference nicotine patch or test nicotine patch (as per the assigned sequence), were applied on participant's upper back or arm. Area under the plasma concentration time curve from zero and extrapolated to the time of last quantifiable sample was determined by plasma concentration time profile of nicotine. Blood samples were drawn at the following time intervals: immediately pre-dose and at 0.5, 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 20, 24, 25, 26, 28, and 32 hours after the application of the patch. Patch was then removed after the collection of 24 hour blood sample. AUC(0 -t) was based on the baseline adjusted nicotine plasma concentration data.
Time frame: Baseline to 32 hours
Maximum Measured Plasma Concentration (Cmax)
Following randomization, the nicotine patches; reference nicotine patch or test nicotine patch (as per the assigned sequence), were applied on participant's upper back or arm. Maximum plasma nicotine concentration was determined from plasma concentration time profiles. Blood samples were drawn at various time points: immediately pre-dose and at 0.5, 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 20, 24, 25, 26, 28, and 32 hours after application the patch. Patch was then removed after the collection of 24 hour blood sample. Cmax was based on the baseline adjusted nicotine plasma concentration data.
Time frame: Baseline to 32 hours
Area Under the Concentration Time Curve Between Zero and Infinity, AUC (0-inf)
Following randomization, the nicotine patches; reference nicotine patch or test nicotine patch (as per the assigned sequence), were applied on participant's upper back or arm. Area under the plasma nicotine concentration time curve from zero extrapolated to infinity was determined by plasma concentration time profile of nicotine. Blood samples drawn at various time points including: immediately pre-dose and at 0.5, 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 20, 24, 25, 26, 28, and 32 hours after wearing the patch. Patch was then removed after the collection of 24 hour blood sample. AUC(0 -inf) was based on the baseline adjusted nicotine plasma concentration data.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Time frame: Baseline to 32 hours
Time to Maximum Plasma Concentration (Tmax)
Following randomization, the nicotine patches; reference nicotine patch or test nicotine patch (as per the assigned sequence), were applied on participant's upper back or arm. Time to Maximum Plasma Concentration was determined from plasma concentration time profiles. Blood samples were drawn at various time points; immediately pre-dose and at 0.5, 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 20, 24, 25, 26, 28, and 32 hours after application of the patch. Patch was then removed after the collection of 24 hour blood sample. Tmax was based on the baseline adjusted nicotine plasma concentration data.
Time frame: Baseline to 32 hours
Plasma Half-life (t1/2)
Following randomization, the nicotine patches; reference nicotine patch or test nicotine patch (as per the assigned sequence), were applied on participant's upper back or arm. The elimination half-life of nicotine was determined by from plasma concentration time profiles. Blood samples were drawn at several time points: immediately pre-dose, and at 0.5, 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 20, 24, 25, 26, 28, and 32 hours after the application of the patch. Patch was then removed after the collection of 24 hour blood sample. Plasma half-life (t1/2) was based on the baseline adjusted nicotine plasma concentration data
Time frame: Baseline to 32 hours
Rate of Elimination (Kel)
Following randomization, the nicotine patches; reference nicotine patch or test nicotine patch (as per the assigned sequence), were applied on participant's upper back or arm. Elimination rate constant for nicotine was determined from plasma concentration time profiles. Blood samples were drawn at several time points: immediately pre-dose, and at 0.5, 1, 2, 3, 4, 5, 6, 8, 10, 12, 14, 16, 20, 24, 25, 26, 28, and 32 hours the application of the patch. Patch was then removed after the collection of 24 hour blood sample. Elimination rate constant for nicotine was based on the baseline adjusted nicotine plasma concentration data.
Time frame: Baseline to 32 hours