The new technical of ultrasonic exploration of this project purpose to validate the measurement of cerebral pulsatility by a new way called "Fast Cerebral Pulsatility Imaging" (FCPI).This will somehow determine the natural history of cerebral pulsatility during development adult to old age
Main objective Phase 1: -Study the in-vivo development of ultrasonic method in terms of quality of the acquisitions and intra-operator reproducibility. Study the ease of positioning in relation to MRI and fusion of MRI and FCPI data via the neuro-navigation system Phase 2: -Study the variability of cerebral pulsatility of measured by "Fast Cerebral Pulsatility Imaging" or FCPI with age. Secondary objectives * Compare the results of displacements cartography's and vascular cartography obtained by MRI (especially by Arteriel Spin Labelling = ASL) * Compare results of FCPI with results of cognitive tests of aging separating fluid functions (prefrontal) and functions called crystallized; and study the residual effect of age on cognitive tasks and speed of cognitive processing after taking into account the effect of the cerebral pulsatility * Compare results of FCPI with electrophysiological measures (PE EEG) describing the attentional control * Perform an exploratory analysis to highlight the propagating part of the brain displacement maps
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
HEALTH_SERVICES_RESEARCH
Masking
NONE
Enrollment
53
Cerebral ultrasonic exploration using with neuro-navigation system : 4 acquisitions on 12 or 6 section planes
University Hospital of Tours
Tours, France
Phase 1 : to validate the technical procedure, we will appreciate several parameters
* Time of implementation of procedure * Qualitative identification of anatomical landmarks of positioning in space of the US probe using neuro-navigation system; if available quantitative measure: x,y,z or distance to a region of interest(ROI) * Perfusion values: Cerebral Blood Flow of Willis' Circle in MRI * Signal to noise ratio * Amplitude (max displacement value), location (x,y,z of location of this max or distance to a ROI) of FCPI * Bandwidth of metrology of FCPI * Possibility to indentify the propagation phenomenon underlying to displacements (speed and attenuation of the shear wave)
Time frame: up to 8 days after consent
Phase 2 : the primary outcome measures will be the maximum amplitude and the average amplitude of cerebral movements
We hypothesize that the variables describing the FCPI will decrease with age. The primary outcome measures will be the maximum amplitude and the average amplitude of cerebral movements measured in µm in planes chosen previously (for example plan of Circle of Willis and a plane including the dorsolateral area of prefrontal cortex).
Time frame: up to 8 days after consent
Phase 2 : Maps of cerebral displacementand tissular perfusion maps
Maps of cerebral displacement obtained by ultrasounds (amplitudes in µm and location in mm) and tissular perfusion maps obtained by Arterial Spin Labelling (Cerebral Blood Flow in µL.g-1.mn-1)
Time frame: up to 8 days after consent
Phase 2 : Measures of FCPI on the regions of interest and cognitive tests
Measures of FCPI on the regions of interest: amplitude (maximum displacement values, µm) and location x, y, z, of the location of this maximum in mm, or distance to a region of interest) on the hand and cognitive tests on the other hand expressed with a numerical score for each test.
Time frame: up to 8 days after consent
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Phase 2 : Measures of FCPI on the regions of interestand measures of PE EEG
Measures of FCPI on the regions of interest: amplitude (maximum displacement values, µm) and location x, y, z, of the location of this maximum in mm, or distance to a region of interest) on the hand and measures of PE EEG on the other hand expressed in terms of amplitude (µV), latency (ms), duration (ms)
Time frame: up to 8 days after consent
Phase 2 : The signal to noise ratio
The signal to noise ratio of maps speed (m/s) and attenuation α (cm-1) of the shear wave obtained by mathematical processing of displacement maps
Time frame: up to 8 days after consent