An adnexal mass is the most common indication for gynaecological surgery . Pre operative characterization is crucial and a scoring system would be useful to standardize the imaging report and thus, improve patient management. Recently, our center developed the first MR scoring system named ADNEXMR SCORING system in a retrospective study which is accurate and reproducible (1). Our objectives are to perform an external prospective validation of this scoring system, to evaluate its potential impact on therapeutic strategy and to test its reproducibility. This is a prospective large multicenter study. All patients with a sonographically indeterminate adnexal mass referred for MR imaging will be consecutively included in each center. Then, patients will undergo a routine pelvic MR imaging. Prospectively, one senior and one junior radiologists independently analyze the different MR criteria to characterize adnexal masses. The MR report will be issued as standard and the patient will be managed accordingly. Then, the reader will classify the mass using ADNEXMR SCORING system. The classification will be compared to the reference standard as defined below. The reproducibility of the classification will be tested between the junior and the senior radiologist. After anonymisation, images will be analyzed by another senior radiologist of another center blinded from any clinical or ultrasonographical data and correlated with the reference standard. Reference standard: Reference standard will be surgical procedure with histology or standard clinical follow-up depending on most appropriate routine practice. Sample size: The sample size was computed to ensure a power of at least 90% (with a two-sided type I error rate of 5%) to conclude that SCORE 2 and 3 and SCORE 4 and 5 would have a different PPV. It would thus be necessary to have at least 569 patients classified as SCORE 2, 259 as SCORE 3, 52 as SCORE 4 and 51 as SCORE 5 (18). Given the prevalences, and assuming 6% of patients would be classified, as SCORE 1 and 10% would be lost to follow-up, 1340 patients will be included in this study to insure a probability of at least 95% to obtain the aforementioned number of patients in each score category. The inclusion period will last 18 months (extension for a period of 12 months) and monitoring will continue for 2 years. Thomassin Naggara I., et al. Development and preliminary validation of an MRI Scoring system for Adnexal Masses. Radiology 2013, May;267(2):432-43.
All patients with an indeterminate ultrasonographically adnexal mass referred for MR imaging will be consecutively included in each center. Inclusion Criteria * Patient ≥ 18 years old * With indeterminate ultrasonographic adnexal mass * Informed consent Non inclusion Criteria * Pregnant women * Pacemaker, ferromagnetic materials, or foreign body at risk of mobilization * Intolerance to iodinated or gadolinium contrast agents, or severe renal insufficiency (GFR \<30 ml/min/1.73m²). Objectives • Primary objective: Evaluate if ADNEXMR SCORING system is relevant for reporting pelvic magnetic resonance imaging (MRI) examinations performed for characterization of sonographically indeterminate adnexal masses in an external prospective multicenter study • Secondary objectives and endpoints: Evaluate 1. The potential impact of applying the score to the therapeutic strategy, in particular to measure the possible reduction in oncologic surgery in benign cases 2. If ADNEXMR SCORING system improves reproducibility of MR report for characterization of adnexal masses 3. If ADNEXMR SCORING system is as accurate if the radiologist is blinded from any clinical and ultrasonographic data Main endpoint Joint analysis of true negative and false negative rates according to ADNEXMR SCORING system as compared to the histological results (or follow-up outcome, see "reference standard", below) with an evaluation of the sensitivity and the specificity of the score
Study Type
OBSERVATIONAL
Enrollment
1,340
University Institute of Radiology
Salzburg, Austria
University Hospital Dubrav
Zagreb, Croatia
Centre Oscar Lambret
Lille, France
Hopital de la Timone
Marseille, France
Institut Paoli Calmettes
Marseille, France
Hopital de Lapeyronie
Montpellier, France
Tenon Hospital
Paris, France
Centre imagerie Pyramides
Paris, France
Hopital Européen Georges Pompidou
Paris, France
Hopital Lariboisière
Paris, France
...and 14 more locations
External validation of Adnex MR scoring system
Evaluate if ADNEXMR SCORING system is relevant for reporting pelvic magnetic resonance imaging (MRI) examinations performed for characterization of sonographically indeterminate adnexal masses in an external prospective multicenter study
Time frame: 24 months
Potential reduction of unnecessary surgery
The potential impact of applying the score to the therapeutic strategy, in particular to measure the possible reduction in unnecessary surgery in benign cases
Time frame: 24 months
Reproducibility of the score
If ADNEXMR SCORING system improves reproducibility of MR report for characterization of adnexal masses
Time frame: 24 months
Comparison between a blinded and an unblinded radiologist regarding sonographic data
If ADNEXMR SCORING system is as accurate if the radiologist is blinded from any clinical and ultrasonographic data
Time frame: 24 months
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.