The iFRCT study is a prospective, multicenter study to evaluate the diagnostic performance of iFRCT with the use of ≥64-detector row CT scanners for the detection and exclusion of significant obstructive coronary artery disease, defined by invasive fractiona flow reserve (FFR) as the reference standard.
Noninvasive fractional flow reserve (FFR) computed from CT (FFRCT) is a novel method for determining the physiologic significance of coronary artery disease (CAD), and several clinical trials have revealed that the FFRCT has a good correlation with invasive FFR, also use of noninvasive FFRCT plus Computed Tomography (CT ) among stable patients with suspected or known CAD was associated with improved diagnostic accuracy and discrimination vs CT alone for the diagnosis of hemodynamically significant CAD. The cornerstone of FFR is the linear relationship between pressure and flow under conditions of constant (and minimized) intracoronary resistance, so is FFRCT. Under such conditions, pressure and flow are assumed to be directly proportional, and a decrease in pressure across a stenosis reflects a decrease in blood flow to the dependent myocardium. However, even after administration of potent pharmacologic agents such as adenosine, intracoronary resistance is not static, but instead fluctuates in a phasic pattern throughout the cardiac cycle. In addition, for patients who are allergic to pharmacologic agents or with sever lesions which response little to pharmacologic agents, the measurement of FFR is challenging and the lesion are always underestimated. The ADVISE trial revealed that intracoronary resistance is naturally constant and minimized during the wave-free period. The instantaneous wave-free ratio calculated over this period produces a drug-free index of stenosis severity comparable to FFR. But whether iFR calculated from Computed Tomography(iFRCT) is comparable to FFRCT or FFR, and its diagnostic performance remains unknown. Thus the investigators conduct this trial to assess the diagnostic performance of Instantaneous Wave-Free Ratio for diagnosis of hemodynamically significant coronary stenosis. Instantaneous Wave-Free Ratio calculated from reconstructed heart model.Wave-intensity analysis identified a wave-free period in which intracoronary resistance at rest is similar in variability and magnitude.The investigators define the resting distal-to-proximal pressure ratio during this period as the instantaneous wave-free ratio (iFR).
Study Type
INTERVENTIONAL
Allocation
NA
Purpose
DIAGNOSTIC
Masking
TRIPLE
Enrollment
100
Fractional flow reserve measured during cardiac catheterization--A pressure-monitoring guidewire(PressureWire Certus, St. Jude Medical Systems, Uppsala, Sweden) will be advanced past the stenosis.
Department of Cardiology, Shanghai Tenth People's Hospital
Shanghai, China
Diagnostic Accuracy of iFRCT
Diagnostic accuracy\[Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV)\]\* of CCTA plus iFRCT(instantaneous wave-free ratio calculated in reconstructed heart model) or iFRCT alone to determine presence or absence of at least one hemodynamically (HD)-significant coronary artery stenosis at the subject level using binary outcomes when compared to FFR as the reference standard.\*Sensitivity measures the proportion of actual positives which are correctly identified. Specificity measures the proportion of negatives which are correctly identified;PPV, or precision rate is the proportion of positive test results that are true positives (such as correct diagnoses);NPV is defined as the proportion of subjects with a negative test result who are correctly diagnosed.
Time frame: 1 day
Diagnostic accuracy of iFRCT at the subject level
Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of CCTA plus iFRCT or iFRCT alone at the subject level using binary outcomes when compared to FFR as the reference standard.
Time frame: 1 day
Diagnostic accuracy of iFRCT at the vessel level
Sensitivity, specificity, PPV and NPV of CCTA plus iFRCT or iFRCT alone for the presence or absence of HD-significant coronary artery stenosis at the vessel level using binary outcomes when compared to FFR as the reference standard.
Time frame: 1 day
FFR Numerical Correlation
Per-vessel correlation of the iFRCT numerical value alone with the FFR numerical value measured during cardiac catheterization.
Time frame: 1 day
FFRCT Numerical Correlation
Per-vessel correlation of the iFRCT numerical value alone with the FFRCT numerical value calculated from the computed tomography.
This platform is for informational purposes only and does not constitute medical advice. Always consult a qualified healthcare professional.
Time frame: 1 day
Predicted Post-PCI FFR Measurement
Diagnostic accuracy of predicted post-percutaneous intervention (PCI) iFRCT alone to determine success or failure of PCI\* using binary outcomes when compared to post-PCI FFR at the subject and vessel level using PCI as the reference standard.\*PCI success will be defined as post-PCI FFR\>0.80, while PCI failure will be defined as post-PCI FFR≤0.80 during adenosine-mediated hyperemia.
Time frame: 1 day